Hdsl Alarm Types Screen; Hdsl Alarm Threshold Fields - ADC PG-PLUS PLL-720 Technical Practice

Table of Contents

Advertisement

Configuration Submenu
Threshold
Errored Seconds (ES 15 Min)
Errored Seconds (ES 24 Hr )
Unavailable Seconds (UAS 15
Min)
Unavailable Seconds (UAS 24 Hr) 0 to 86400
Low Margin (MAR)

HDSL Alarm Types Screen

Allows the provisioning of the alarm types for all HDSL
shows the HDSL Alarms, the possible alarm Types, and the default factory settings. You can view the results of
these settings from the
1.
At the CONFIG submenu, select HDSL Alarm Types, and press
2.
You can perform the following tasks:
a. To change the value of the COLU alarm Loss of Sync Word, select the field in the
and press the
SPACEBAR
b. To change the value of the COLU alarm Errored Seconds (ES 15 Min), select the field in the
column, and press the
c. To change the value of the COLU alarm Errored Seconds (ES 24 Hr), select the field in the
column, and press the
d. To change the value of the COLU alarm Unavailable Seconds (UAS 15 Min), select the field in the
column, and press the
TYPE
42
Table 10.

HDSL Alarm Threshold Fields

Values
Description
0 to 900
Value for the HDSL 15 minute interval ES alarm.
0 to 86400
Value for the HDSL 24 hour interval ES alarm.
0 to 900
Threshold value for the HDSL 15 minute interval UAS alarm.
Threshold value for the HDSL 24 hour interval UAS alarm.
0 to 25
Value at which alarm is set active if margin drops equal to or
less than this threshold.
"HDSL History Screen" on page
to toggle to the desired value.
to toggle to the desired value.
SPACEBAR
to toggle to the desired value.
SPACEBAR
to toggle to the desired value.
SPACEBAR
January 6, 2003
Alarms.Table 10
lists the Alarm Reports and
30.
to view the screen.
ENTER
SCP-PLL720-020-03H
Default
17
170
240
600
06
Table 12
column,
COLU TYPE
COLU TYPE
COLU TYPE
COLU
PLL-720, PLL-721 List 2's