System Status - ADC PG-PLUS PLL-720 Technical Practice

Table of Contents

Advertisement

SCP-PLL720-020-03H
Status
Description

System Status

IN SYNC
No CO battery detected, Line Status Open. This status does not change except for Test status
OUT OF SYNC
CO battery detected and line is Onhook at RTs
HDSL Status
HDSL LINK DOWN HDSL link is down and System is not in Metallic Fallback.
NORMAL
HDSL link is synchronized.
START-UP
HDSL link is acquiring synchronization.
METALLIC
HDSL link is down and System is in Metallic Fallback
FALLBACK
Alarm Status
HDSL
Summary of alarms associated with HDSL link.
SYSTEM
Summary of alarms within the system.
Channel Status
BUSY
Line is off-hook at RT.
FRAMED
The DSL startup sequence is complete, but end-to-end transparency has not been established.
IDLE
CO battery detected and line is on-hook at RT.
LOS
Loss of signal.
N/A
Not applicable.
OPEN
No CO battery detected, Line Status Open. This status does not change except for Test status.
IDLE
CO battery detected and line is on-hook at RT
RINGING
Line is ringing.
RINGGND
Ring ground detected at the RT.
REVERSED
CO battery is detected with Tip and Ring reversed.
TEST
Testing being done on line.
Channel Status for POTS during Metallic Fallback and HDSL Startup
N/A
Invalid until HDSL is in SYNC, or if Metallic Fallback has been disabled
METALLIC
POTS #1 line status when system is in Metallic Fallback, if Metallic Fallback has been enabled
FALLBACK
PLL-720, PLL-721 List 2's
Table 5.
System Status
January 6, 2003
COLU Main Screen
19