Download Print this page

Specification - Sealey SPACE WARMER AB2380 Manual

240,000btu/hr, 340,000btu/hr kerosene/ diesel heater

Advertisement

DO NOT unplug the heater to switch it off. Use the ON/OFF switch.
8
WARNING! Improper maintenance can lead to poor combustion and soot production
NOTE:
This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they DO NOT play with the appliance.
Unplug the heater before moving it. Never pull the cable to unplug or move the unit.
9
8
DO NOT leave the heater unattended when in use.
8
Never use the appliance with wet hands or when either the heater or the power cable is wet.
If the supply cable is damaged, it must be replaced by the manufacturer, by a service agent or a similar qualified person.
9
WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that may
occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but
must be applied by the operator.
WARNING! Air contaminants taken into the heater may affect the heat output, damage the unit and may cause health
problems. Example: Bodyshop filler dust or paint overspray will damage the motor bearing, clog the filter and compressor
and contaminate the combustion chamber causing flame flutter and health hazards. Please note that any parts damaged by
filler dust or overspray will not be covered by warranty.
2. INTRODUCTION
Workshop tried and tested, our range of Kerosene/Diesel heaters represents excellent value. The range includes two economy portable units,
Model No's AB458 and AB708, which are both supplied without wheels. All models have a digital adjustable thermostat (°C) and are also
fitted with digital room temperature (°C) display/error code read-out (Except Model No. AB2050, this has no digital display but can still be
thermostatically controlled). Proven pump systems handle either kerosene or diesel with only minor adjustment of air compressor. All models are
fitted with a fuel tank gauge and heavy-duty fuel cap. Model No's AB7081, AB1008, AB1258, AB1758, AB2158, AB2380 and AB3412 are fitted
with fuel tank drain plug, sturdy handle and heavy-duty wheels for easy manoeuvrability. AB2380 and AB3412 are also equipped with Danfoss oil
nozzle and gear pump for stable fuel delivery.

3. SPECIFICATION

MODEL NO.
Airflow (cfm)
Electrical fuse rating
Electrical Plug type
Fuel
Fuel tank
Heated area
Motor power
Output
Running time per filling (max.)
Supply
Transport wheels
4. CONTENTS
fig.1
H
J
G
I
© Jack Sealey Limited
AB2380
765
13A
3-pin BS
Kerosene/Diesel
69L
70,600ft³(2000m³)
430W
240,000Btu/hr(70kW)
10hr
230V - 13A
Yes
B
C
K
F
Original Language Version
AB3412.V2
825
88,200ft³(2500m³)
340,000Btu/hr (100kW)
7hr
No.
A
A
B
C
D
E
F
D
G
H
I
J
E
fig.1
K
AB2380, AB3412.V2
Description
Qty.
Handle
1
10/12
Screw
6/8
Spring washer
10/12
Plain washer
Frame
1
Nut M5
10/12
Nut M12
2
Wheel
2
ø
2
Plain washer
12
Axle
1
Split pin
2
Issue 1
23/05/2022

Advertisement

loading

This manual is also suitable for:

Space warmer ab3412.vSpace warmer ab3412Space warmer ab3412.v2