Download Print this page

Operational Precautions; Specification - Sealey EH5001.V2 Quick Start Manual

Industrial fan heaters btu/hr: 17,000, 31,000, 51,000: output 5kw, 9kw, 15kw

Advertisement

Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unapproved parts may be dangerous and will invalidate the warranty.
9
DO NOT attempt to repair a damaged heater, contact an authorised service agent.
8
WARNING! In order to avoid overheating, DO NOT cover the heater.
1.3.
POSITIONING OF HEATER
WARNING: To reduce the risk of fire, keep textiles, curtains, or any other flammable material a minimum distance of 1m from the heat
source.
WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
Use this heater on a horizontal and stable surface.
9
DO NOT place the heater close to a bath, wash basin, shower, swimming pool or any other water-filled area or wet surface.
8
DO NOT place the heater up against any surface such as a wall, door or furniture etc.
8
DO NOT place the heater immediately below any electrical outlet.
8
DO NOT place the heater on a raised surface or anywhere where it could topple over.
8
DO NOT get the heater wet or use in areas of high condensation.
8
DO NOT allow the power lead to touch hot surfaces.
8
DO NOT connect the heater to a timer device or other equipment than can automatically switch the heater on or off.
8
DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT stand on the heater.
8
DO NOT use the heater with wet hands or when there is water on the power cord.
8
DO NOT use the heater for anything other than its intended purpose. It is designed to provide heat in enclosed areas such as
8
workshops and other industrial areas. It is not suitable for drying clothes or laundry.
Position the heater at least a minimum of 1m at the front, rear and sides from any walls or objects.
9
If an extension cable is required it must be of the same cross section as the heater cable. It must be as short as possible and fully
9
unwound.
Ensure that the heater is correctly turned off when not in use and store in a safe, dry, childproof location.
9
1.4.

OPERATIONAL PRECAUTIONS

The heater must only be used by people who have read these instructions and have been trained in its use.
9
DO NOT obstruct the air inlet and outlet sections of the heater.
8
WARNING! In order to avoid overheating, DO NOT cover the heater.
DO NOT use the heater without the grille fitted.
8
DO NOT use if the heater has been dropped.
8
DO NOT use if there are visible signs of damage to the heater.
8
DO NOT touch the heater casing or grille when first switched off, as these will be very hot and will take time to cool.
8
NOTE: Children of less than 3 years should be kept away unless supervised continuously.
Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its
intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or
perform user maintenance.
CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and
vulnerable people are present.
NOTE: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
2. INTRODUCTION
Electric fan heaters for industrial applications. Model No's EH5001, EH9001 and EH30001 feature two heat settings and fan only option. Model
No. EH15001 features three heat settings and adjustable thermostat control with fan only option. Auto cooling system to prevent unit from
overheating during use. A totally dry heat with no condensation, no gas, no fumes and no smell. Ideal for workshops and garages. Model No's
EH5001 and EH9001 supplied with 3-phase power cable and 16A plug. Model No's EH15001 and EH30001 supplied with 3-phase chassis
mounted 5-pin connector (extension cable required).

3. SPECIFICATION

Model No.
Heated Area:
Output: Btu/hr
Plug Type:
Power Supply Cable Length:
Power:
Supply:
IMPORTANT!
This unit is designed to raise the ambient temperature of an entire room, the temperature of the air coming out of the front of the
heater will be warmer than the general temperature of the room, but there may not be a significant increase owing to the large
volume of air passing over the element. For the same reason, the element is hot during operation, but does not glow. The room
temperature depends on room size, insulation and ambient temperature, which will increase as the room warms.
ASS
© Jack Sealey Limited
EH5001.V2
EH9001.V2
48m
80m
3
3
17,000
31,000
Red - 16A-4P+E
Red - 16A-4P+E
1.2m
1.2m
2500/5000W
4500/9000W
415/3ph-16A
415/3PH - 16A
Original Language Version
EH15001.V2
120m
3
51,000
Red - 32A-4P+E
N/A
7500/15000
415/3ph-32A
EH15001.V2, EH9001.V2, EH5001.V2 Issue 1 01/06/23

Advertisement

loading

This manual is also suitable for:

Eh9001.v2Eh15001.v2