AB2380 ERROR CODES
PROBLEM
CAUSE
Motor does not start
No power or low voltage
Faulty or damaged power cord
E1 displayed on
Faulty motor/capacitor
screen
Lock-out of appliance due to previous
overheating
E2 displayed on
The temperature probe is faulty or the
screen
connector for temperature probe is loose
Motor runs, but the
Empty fuel tank, dirty or wrong fuel
heater does not ignite
and locks out after a
Ignition fault, dirty or incorrect electrods
short time
position
E1 displayed on the
Fuel filter clogged
screen
Burner nozzle clogged
Fuel viscosity increased at low temperature
Insufficient airflow into combustion chamber
Heater starts but
combustion is poor
Wrong fuel pressure
Leaks in fuel line
Heater stops during
The room temperature set on room
operation
thermostat has been reached
Ambient temperature
displayed on the
screen
Heater stops during
Flame failure
operation
Poor combustion
Reduced airflow
E1 displayed on the
screen
Overheating
Failed 3 times for igniting will lock the PCB
LC displayed on the
screen
and stop working

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
01284 703534
sales@sealey.co.uk
Original Language Version
REMEDY
Check power line and voltage
Check fuse and replace if necessary
Check and replace if needed
Check and if necessary replace
Detect the cause of overheating
Shut the appliance down
Check air inlet and outlet
Wait some minutes and restart the appliance
Check and replace if the temperature probe if needed
Check and replace the PCB if needed
Remove wrong or dirty fuel
Fill the tank with clean Diesel or kerosene
Check and clean electrodes
Clean or replace fuel filter
Clean nozzle blowing compressed air, replace if necessary
Mix Diesel with 10-20% kerosene
Check air inlet, fan, motor and air collar position, adjust it if
necessary.
Check fuel pressure, adjust it if needed
Check and fix fuel leaks
Normal operation
To start turn the temperature control knob clockwise on a higher
setting
Check and remove the cause(s) of malfunction
To reset, turn On/Off switch to 0 and then to I
Call technical service if the problem persists
With electricity on, it will be unlocked after 3 times power switch to
ON in 10 seconds;
AB2380, AB3412.V2