Mitsubishi Electric KD Series User Manual page 73

Contact image sensor for web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

5-2 Setting ⑪ γ correction
5-2-11 γ correction function
【 Input 】
Command Parameter ( DATA ) ( DATA ) CR
GC
**
Upper
Lower
【 Output 】
Result Parameter ( DATA ) ( DATA ) CR
**
**
Upper
Lower
CR
* a gain is defined by 2 byte data . Commands except for setting a gain have
no data.
[initial]
γ correction
: OFF ( γ =1 )
Preset γ table : γ=2.2
[setting]
γ correction ON/OFF
出力
変換後データ
Example
0 LSB
Switch γ correction turn on
GC 00 <CR>
⇒ 00 00 <CR>
TM-XG537C
CR
γテーブル
ガンマテ ーブル閾値
GMSH_01
GMSH_02
GMSH_03
1024
領域 1
領域 2
領域 0
76 8
領域 3
51 2
25 6
25 6
51 2
76 8
10 24
入力
領域 0
領域 1
領域 2
領域 3
0 ~ 12 8 階調
129 ~ 34 6 階調
347 ~ 640 階調
641 ~ 1023 階調
9
0
0
1
1
8
0
1
0
1
7
6
5
4
8bit-SRAM
8bit-SRAM
8bit-SRAM
8bit-SRAM
FFh~00h
FFh~00h
FFh~00h
FFh~00h
3
2
1
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【 γ correction function 】
[Function]
Change the linearity from input data to output data by LUT .
* LUT : Look Up Table
The output property of Photo-diodes on sensor ICs against
light power input is linear.
This function change the of Input-Output property (γ) to fit
visible images .
【 Remarks 】
1) γ table consists of 4 of LUT which made output
correspond to 256 of input which shared 1024 steps
with 4 groups.
2) Refer the function specification about details of γ
correction function .