5-2 Setting ② Set output CLK frequency
5-2-2 Output CLK frequency setting
【 Input 】
Command Parameter End code
OF
**
CR
[initial value] 84MHz ( maximum CLK frequency)
[Range of setting] 48MH z - 84MH z
the selectable CLK frequency is following.
Parameter
frequency
Rad value
00
48MH z
-
01
50.7MHz
-
02
51.0MHz
-
03
51.4MHz
-
04
52.0MHz
-
05
52.8MHz
-
06
53.3MHz
-
07
54.0MHz
-
08
54.9MHz
-
09
56MHz
-
0A
57MHz
-
0B
57.6MHz
-
0C
58.3MHz
-
0D
60MHz
-
0E
61.7MHz
-
0F
62.4MHz
-
Example
Select output CLK frequency on 66MHz
OF 12 <CR>
⇒
TM-XG537C
【 Output 】
Result Parameter End code
**
**
CR
parameter
Frequency
Read value
10
64MHz
-
11
65.1MHz
-
12
66MHz
-
13
67.2MHz
-
14
68MHz
-
15
68.6MHz
-
16
72MHz
-
17
76MHz
-
18
76.8MHz
-
19
78MHz
-
1A
80MHz
-
1B
81.6MHz
-
1C
84MHz
-
80
READ setting
00 - 1C
00 12 <CR>
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【 Output CLK frequency setting 】
[Function]
Pixel CLK frequency of Camera Link® I/F is set by this
command .
Scanning rate and amount of output data per line should
be considered to define pixel CLK frequency
[Remarks]
1) The relationship between Pixel CLK frequency and
scanning line rate should be satisfied with following
equations.
x= The number of pixels per 1ch 1tap
(Refer to Appendix A ③ , ④ , ⑦ for x of each mode)
① In the case of Base Configuration
CLK frequency (MHz) > ( + 30) × Line frequency (kHz)
② In the case of Medium Configuration
CLK frequency (MHz) > ( + 30) × Line frequency (kHz)
③ In the case of Medium Configuration 2
CLK frequency (MHz) > ( + 30) × Line frequency (kHz)
④ In the case of Medium Configuration 3
CLK frequency (MHz) > (
2) Refer the function specification for more information .
3) Use parameter value only in the table . If a parameter
value is not in the table , data output will be not correct .
Camera Link® is a registered trademark of AIA(Automated Imaging Association)
+ 30) × Line frequency (kHz)