Installation Instructions - Endress+Hauser Soliswitch FTE20 Operating Instructions Manual

Point level switch
Hide thumbs Also See for Soliswitch FTE20:
Table of Contents

Advertisement

Soliswitch FTE20
å 3
Incorrect installation positions of the point level switch
6:
In direction of solids flow
7:
Installation coupling too long
8:
Horizontal with shaft length >300 mm (11.8 in)
Ambient temperature range
–20 to 60 °C (–4 to 140 °F)
Medium temperature range
–20 to 80 °C (–4 to 176 °F)
More information is provided in the "Technical data" section (® ä 23).
4.3

Installation instructions

NOTICE
The device can be damaged if handled incorrectly during installation
Do not turn the housing to tighten the process connection. Once the process connection has
been tightened, the housing can be aligned so that the cable entries point downwards.
Endress+Hauser
Installation
6
7
8
mm (in)
A0017074
11

Advertisement

Table of Contents
loading

Table of Contents