Features

The Product features:
Traceable voltage, current, and power signals
Configurable from one to three independent phases
Full independent control of voltage and current on each phase
600 V ac (280 V dc) and 30 A available on each phase
Up to 300 mA burden current on voltage outputs
5.5 V peak compliance on all current outputs up to 30 A
High-current mode that generates up to 90 A into a single output
Optional Energy counter (6003A/E Energy Option).
o Frequency input for counting energy meter outputs up to 1 MHz
o Pulse output proportional to Energy output, up to 1 MHz
Optional Power Quality features (6003A/PQ Power Quality Option)
o Non-sinusoidal voltage and current outputs with up to 63 harmonics
and 1 interharmonic
o Dips and swells on both voltage and current
o Modulation to simulate flicker
o User-definable waveforms, with the ability to save the actual setting
into internal memory

Specifications

This section gives the general and detailed specifications of the Product.

Input Power

Voltage
Frequency
Maximum consumption

Dimensions

Height
Height (without feet)
Width
Depth
Weight
115 V, 230 V ±10 %
47 Hz to 63 Hz
1875 VA max
415 mm (16.3 inches)
402 mm (15.8 inches)
430 mm (16.9 inches)
640 mm (25.2 inches)
62 kg (136 lb)