characters for one of the "HEX" formats or an incorrect number of
digits for a parameter defining an EPC-format.
Problem:
TAGREAD commands yield "Tag format error" error messages.
Possible Causes and Suggested Remedies:
• The number of required parameters depend on what TAGFORMAT
has been defined for the read operation.
-
See the manual for Fingerprint v8.60 or later. Additional
information can be found in the EPC Tag Data Standard (v1.1,
revision 1.27) document available via http://www.epcglobalinc.
org/standards_technology/specifications.html.
Problem:
The message "Error in filename" (Fingerprint) or "No RFID support"
(IPL) is displayed when attempting to enable RFID mode through setup,
for example by calling the command SETUP "RFID,MODE,ENABLE".
Possible Causes and Suggested Remedies:
• No RFID kit is installed in the printer.
Problem:
ISO 18000-6B tags work fine, but reading Class 1 tags yield a "No tag
found" error message.
Possible Causes and Suggested Remedies:
• ISO 18000-6B tags are addressed with the IM3 or IM5 RFID
reader. For these modules, Class 1 support has not been
implemented yet. Class 1 tags require an MPR6100 RFID Radio
Module.
-
An MPR6100 can be ordered from Intermec Sales as part of an
upgrade kit ("RFID Kit (Class 1, 915 MHz").