SLM
Name
Pin
com
com\
Drive-status supply
Hardware enable
24V SLM supply
0V COMMON
(No connections)
Cable shield
Shell
MC
Name
Pin
com
com\
Drive-status supply
Hardware enable
(No connections)
0V COMMON
SLM-and-user back-up
supply
Cable shield
Shell
8
7
6
5
4
3
2
1
Figure A.5 RJ45 connector pin-locations (as seen from the top of
the Drive)
82
I/O
Function
1
)
t echnology port for communication
I/O
2
with the SLM
For use with Drive-status input and output
3
O
connections
4
I
5
O
24V supply to the SLM
6
For use with all the I/O on this connector
7
Do not use
8
Connect the cable shield to the connector
shell
I/O
Function
1
)
t echnology port for communication
I/O
2
with a motion controller
For use with Drive-status input and output
3
O
connections
4
I
5
Do not use
8
6
For use with all the I/O on this connector
7
I
Connect the cable shield to the connector
shell
Specification
2-wire EIA485
100 Ω twisted-pair inside 8-way shielded
cable (see Cables and connectors on page
76)
Current-source supply
Output-voltage compliance: 24V +20%
(See Digital inputs on page 77.)
0V COMMON must not be interchanged
with 0V
Specification
2-wire EIA485
100 Ω twisted-pair inside 8-way shielded
cable (see Cables and connectors on page
76)
Current-source supply
Output-voltage compliance: 24V +20%
(See Digital inputs on page 77.)
0V COMMON must not be interchanged
with 0V
(See Types of back-up supplies on page
17.)
M'Ax User Guide