I Auto repeater
function
(USA version only)
The USA version automatically activates the repeater settings
(duplex, ON/OFF, duplex direction, tone encoder ON/OFF)
when the operating frequency falls within or outside of the
general repeater output frequency range. The offset and re-
peater tone frequencies are not changed by the auto repeater
function, reset these frequencies, if necessary.
➀
While pushing [8] + [0], turn power on to enter initial set
mode.
➁
Push [t] one or more times until "AR" appears.
➂
Push [Y]/[Z] to select the desired condition.
• "oFF"—the auto repeater function is
turned off;
"on1"—the auto repeater function acti-
vates for duplex only;
"on2"—the auto repeater function acti-
vates for duplex and tone.
➃
Turn power off, then on again to exit initial set mode.
INITIAL SET MODE
USING
MR
REPEATER OPERATION
Frequency range and offset direction
FREQUENCY RANGE
145.200–145.495 MHz
146.610–146.995 MHz
147.000–147.395 MHz
5
DUPLEX DIRECTION
"–DUP" appears
"DUP" appears
17