• Command table (continued)
Command
Sub command
0E
A1–A7
B0
B1
D0
D3
0F
00
01
10
11
12
10
00
01
02
03
04
05
06
07
08
11
12
13
00
01
02
14
01 + Level data [AF] level setting (0=max. CCW to
02 + Level data [RF] level setting (0=max. CCW to
03 + Level data [SQL] level setting (0=11 o'clock to
06 + Level data [NR] level setting (0=min. to
07 + Level data Inside [TWIN PBT] setting or IF
08 + Level data Outside [TWIN PBT] setting
09 + Level data [CW PITCH] setting (0=300 Hz,
0A + Level data [RF PWR] setting (0=mini. to
0B + Level data [MIC GAIN] setting (0=mini. to
0C + Level data [KEY SPEED] setting (0=slow to
0D + Level data [NOTCH] setting (0=low freq. to
0E + Level data COMP Level Delay setting (0=0 to
0F + Level data Break-IN DELAY setting (20=2.0d
15
01
02
11
12
13
16
02
Description
Set ∂F scan span (A1=±5 kHz,
A2=±10 kHz, A3=±20 kHz,
A4=±50 kHz, A5=±100 kHz,
A6=±500 kHz, A7=±1 MHz)
Set as non-select channel
Set as select channel
Set scan resume OFF
Set scan resume ON
Turn the split function OFF
Turn the split function ON
Select simplex operation
Select –DUP operation
Select +DUP operation
Select 10 Hz (1 Hz) tuning step
Select 100 Hz tuning step
Select 1 kHz tuning step
Select 5 kHz tuning step
Select 9 kHz tuning step
Select 10 kHz tuning step
Select 12.5 kHz tuning step
Select 20 kHz tuning step
Select 25 kHz tuning step
Select/read attenuator (0=OFF,
1=ON)
Select/read antenna selection
(0=ANT1, 1=ANT2)
Announce with voice synthesizer
(00=all data; 01=frequency and
S-meter level; 02=receive mode)
255=max. CW)
255=11 o'clock)
255=max. CW)
255=max.)
shift setting (0=max. CCW,
128=center, 255=max. CW)
(0=max. CCW, 128=center,
255=max. CW)
128=600 Hz, 255=900 Hz)
255=max.)
255=max.)
255=fast)
255=high freq.)
10=10)
to 130=13.0d)
Read squelch condition
Read S-meter level
Read RF power meter
Read SWR meter
Read ALC meter
Preamp (0=OFF; 1=preamp 1;
2=preamp 2)
CONTROL COMMAND
Command
Sub command
16
12
22
40
41
42
43
44
45
46
47
48
49
4B
4C
19
00
1A
00
01
02
03
04
0501
0502
0503
0504
0505
0506
0507
0508
0509
0510
0511
0512
0513
0514
0515
0516
14
Description
AGC selection (0=OFF; 1=Slow;
2=Mid; 3=Fast)
Noise blanker (0=OFF; 1=ON)
Noise reduction (0=OFF; 1=ON)
Auto notch (0=OFF; 1=ON)
Repeater tone (0=OFF; 1=ON)
Tone squelch (0=OFF; 1=ON)
Speech compressor (0=OFF; 1=ON)
Monitor (0=OFF; 1=ON)
VOX function (0=OFF; 1=ON)
Break-in (0=OFF; 1=semi break-
in; 2=full break-in)
Manual notch (0=OFF; 1=ON)
RTTY filter (0=OFF; 1=ON)
DTCS (0=OFF; 1=ON)
VSC (0=OFF; 1=ON)
Read the transceiver ID
Send/read memory contents (see
p. 97 for details)
Send/read band stacking register
contents (see p. 97 for details)
Send/read memory keyer con-
tents (see p. 97 for details)
Send/read the selected filter width
(0=50 Hz to 40/31=3600/2700 Hz)
Send/read the selected AGC time
constant (0=OFF, 1=0.1/0.3 sec. to
13=6.0/8.0 sec.)
Send/read LCD contrast (0=0% to
255=100%)
Send/read LCD backlight (0=0% to
255=100%)
Send/read beep gain (0=min. to
255=max.)
Send/read beep gain limit (0=OFF,
1=ON)
Send/read calibration marker
(0=OFF, 1=ON)
Send/read confirmation beep
(0=OFF, 1=ON)
Send/read band edge beep
(0=OFF, 1=ON)
Send/read RF/SQL control set
(0=Auto, 1=SQL, 2=RF+SQL)
Send/read meter peak hold set
(0=OFF, 1=ON)
Send/read COMP meter set
(0=OFF, 1=ON)
Send/read quick split set (0=OFF,
1=ON)
Send/read split offset –9.999 to
+9.999 MHz (see p. 98 for details)
Send/read split lock set (0=OFF,
1=ON)
Send/read duplex offset 0.000 to
9.999 MHz for HF (see p. 98 for
details)
Send/read duplex offset 0.000 to
9.999 MHz for 50 MHz band (see
p. 98 for details)
Send/read duplex offset 0.000 to
9.999 MHz for 144 MHz band
(see p. 98 for details)
96

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I746pro

Table of Contents