Download Print this page
Icom IC-746PRO Series Technical Information

Icom IC-746PRO Series Technical Information

Hide thumbs Also See for IC-746PRO Series:

Advertisement

Quick Links

To
: ICOM Distributors
From
: ICOM Inc. / Export Department
Ref No. : SEN-015-03
Date
: December 17, 2003
Re. Improvement of the PA Driver for the IC-746PRO/ 7400 series.
Thank you very much for your continuous strong promotion for our products in your market.
The following is the information for the improvement of the PA driver for the IC-746PRO/ 7400 series.
Model:
All versions of the IC-746PRO/ 7400 series.
Symptom:
No RF power output.
Cause:
The driver transistor on the PA stage will be damaged when the transceiver is used in a high
temperature environment and transmits continuously.
Procedure of this improvement:
For solution of this problem, we have reduced the current drain of the circuitry on the PA stage.
The following is the procedures for this improvement.
(1) Replace the parts as shown in the parts list and parts location.
(2) Replace the MP34 screws which is fixed to the DRV board.
(3) Adjust PA idling current to 1.5A from 2.5A.
Technical
Page. 1 of
Icom Inc.
1-1-32, Kamiminami, Hirano-ku, Osaka, 547-0003
JAPAN
Phone : 06 6793 5302
URL : http://www.icom.co.jp/
Information
Service handling necessary:
[ ] Yes
7
Fax : 06 6793 0013
[X] No

Advertisement

loading

Summary of Contents for Icom IC-746PRO Series

  • Page 1 Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Technical Information : ICOM Distributors From : ICOM Inc. / Export Department Service handling necessary: Ref No. : SEN-015-03 [ ] Yes [X] No Date : December 17, 2003 Re.
  • Page 2 Icom Inc. 1-1-32, Kamiminami, Hirano-ku, Osaka, 547-0003 JAPAN Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Replace following parts. Parts Action Board Number Parts Number (Old) Parts Number(New) Taken Version CHASSIS MP34 8810003170 8810003370 Replaced...
  • Page 3 1-1-32, Kamiminami, Hirano-ku, Osaka, 547-0003 JAPAN Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Parts Location on the PA board. (L6, L2, R41 and R42) Schematic Diagram of the PA board. (L6) Page. 3 of...
  • Page 4 1-1-32, Kamiminami, Hirano-ku, Osaka, 547-0003 JAPAN Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Parts Location on the CTRL board. (D25, D26 and R154) Schematic Diagram of the CTRL board. (D25 and D26) Page. 4 of...
  • Page 5 Icom Inc. 1-1-32, Kamiminami, Hirano-ku, Osaka, 547-0003 JAPAN Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Parts Location on the DRV board. (R11) Schematic Diagram of the DRV board. (R11) Page. 5 of...
  • Page 6 JAPAN Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Replace the MP34 screws on the CHASSIS board which is fixed to the DRV board. Adjust PA Idling current to 1.5A from 2.5A. Page. 6 of...
  • Page 7 1-1-32, Kamiminami, Hirano-ku, Osaka, 547-0003 JAPAN Phone : 06 6793 5302 Fax : 06 6793 0013 URL : http://www.icom.co.jp/ Updated Serial Number: This modification has not yet been applied in production units. However, the serial number of improved units will be announced later.

This manual is also suitable for:

Ic-7400 series