Fault Pop-up
Board Spray Valve
Fault
Hydraulic Valve
Fault
Zamboni FastICE
®
Operating Manual
DK - 11000
Operating Manual
Cause
1. Solenoid coil for the valve that
controls water flow to the upper
boom is not connected
2. Wiring to upper boom valve is
damaged or severed
3. Solenoid coil on the valve
exposed to over-voltage / over-
current and is damaged
1. Solenoid coil for the valve that
controls water flow to the upper
boom is not connected
2. Wiring to upper boom valve is
damaged or severed
3. Solenoid coil on the valve
exposed to over-voltage / over-
current and is damaged
Remedy
1. Verify that valve electrical
connector is connected properly
2. Inspect valve electrical connector
for damage
3. Inspect valve wiring for damage
4. Inspect valve solenoid coil for
damage
5. Verify valve solenoid coil
resistance to be 14.7 Ohms
1. Verify that valve electrical
connector is connected properly
2. Inspect valve electrical connector
for damage
3. Inspect valve wiring for damage
4. Inspect valve solenoid coil for
damage
5. Verify valve solenoid coil
resistance to be 4.5 Ohms
Page 37 of 44