System Fault: Water Flow And Pressure Out Of Range: Low - Zamboni FastICE DK - 11000 Operating Manual

Table of Contents

Advertisement

Incorrect flow coefficient entered within the hidden setting screen (disregard this if the value has not
been changed from its factory setting)
Worn hydraulic motor that drives the water pump
Worn hydraulic pump section that supplies hydraulic oil to the hydraulic manifold
The default setting for this is 8 L/min (2 GPM) below the target flow value for at least 10
seconds. For reference, the flow rate for the Upper spray boom for a traveling speed of 8 km/hr
(5 MPH) is 41 L/min (10.5 GPM), and the flow rate for the Lower spray boom is 14 L/min (3.8
GPM) .

System Fault: Water Flow and Pressure Out of Range: Low!

This pop-up will display when there is a problem with output flow and pressure from the pump being
lower than expected by an amount that exceeds both deviation settings related to water flow and
pressure.
Problems may include:
Clogged water filter
An issue with the flow sensor
Plugged water supply line between the water pump and the water flow meter
Leaking hose connection between the pump and flow meter
Insufficient pump speed and maximum command signal is being sent to hydraulic valve but water flow
is too low