Display Pop-Up System Fault Messages

Detailed information related to system troubleshooting can be found in the "Troubleshooting" section of
this manual.
If a fault condition is activated, the fault can be cleared by cycling the main power switch on the side of the
display enclosure off and then on again. Since the system was already fully booted up when the power
was turned off, the system will immediately turn back on when the power switch is turned back to the
"on" position.

System Fault: Water Pressure Out Of Range: High!

WATER PRESSURE OUT
OF RANGE: HIGH!
This pop-up will display when there is a problem with the water system related to the water system being
clogged.
This pop-up will display when there is a problem with output pressure from the pump being lower than the
target pressure by an amount that exceeds the allowable deviation setting.
Causes may include:
Clogged spray orifice
Clogged spray orifice strainer
Clogged inlet screen on the boom spray water control valve
Damaged spray orifice or spray nozzle body
Restriction in the water hose downstream of the pressure sensor
The default setting for this is 70 kPa (~10 PSI) above the target value for at least 10 seconds. For
reference, the spray pressure for a traveling speed of 8 km/hr (5 MPH) and a flow rate of 54.1 L/
min (14.3 GPM) is 138 kPa (20 PSI).
Zamboni FastICE
®
Operating Manual
DK - 11000
Operating Manual
Page 23 of 44