Chapter 6 - System Troubleshooting

The Zamboni FastICE system features ability for self-diagnosis in the event that it is not performing as
expected.
If a fault condition is activated, the fault can be cleared by cycling the main power switch on the
side of the display enclosure off and then on again. Since the system was already fully booted
up when the power was turned off, the system will immediately turn back on when the power
switch is turned back to the "on" position.
System Faults, Fault Codes and Self-diagnostic Capabilities:
Fault Pop-up
Upper Boom Valve
Fault
Lower Boom Valve
Fault
Zamboni FastICE
®
Operating Manual
DK - 11000
Operating Manual
Cause
1. Solenoid coil for the valve that
controls water flow to the upper
boom is not connected
2. Wiring to upper boom valve is
damaged or severed
3. Solenoid coil on the valve
exposed to over-voltage / over-
current and is damaged
1. Solenoid coil for the valve that
controls water flow to the upper
boom is not connected
2. Wiring to upper boom valve is
damaged or severed
3. Solenoid coil on the valve
exposed to over-voltage / over-
current and is damaged
Remedy
1. Verify that valve electrical
connector is connected properly
2. Inspect valve electrical connector
for damage
3. Inspect valve wiring for damage
4. Inspect valve solenoid coil for
damage
5. Verify valve solenoid coil
resistance to be 22.0 Ohms
1. Verify that valve electrical
connector is connected properly
2. Inspect valve electrical connector
for damage
3. Inspect valve wiring for damage
4. Inspect valve solenoid coil for
damage
5. Verify valve solenoid coil
resistance to be 22.0 Ohms