The electrical supply must be a correctly polarized 120 VAC, 60 Hz, single phase circuit
suitable for the maximum current draw of the model, as detailed in the table below. Verify your
model's current draw by checking the rating label on the back of the range.
This appliance is factory equipped with a power supply cord with a three-prong grounding
plug (with polarized parallel blades). It must be plugged into a mating grounding-type
receptacle, connected to a correctly polarized 120 VAC.
If the circuit does not have a grounding type receptacle, it is the responsibility and obligation
of the installer to have the existing receptacle changed to a properly grounded and polarized
receptacle in accordance with all applicable local codes and ordinances by a qualified
electrician. In the absence of local codes and ordinances, the receptacle replacement shall be
in accordance with the National Electrical Code.
The third prong should not, under ANY circumstances, be cut or removed.
MODEL
MAX. CURRENT DRAW
RGV3-488
RGV3-485GD
RGV3-366
RGV3-304
RGV3-305
This range must be connected to the mains power supply by a suitably qualified person.
z
This range must be grounded.
z
Always disconnect electric supply cord from the wall outlet or service disconnect before
z
servicing this appliance.
Observe all governing codes and ordinances when grounding, in absence of which, observe
z
National Electrical Code ANSI / NFPA No. 70.

ELECTRICAL REQUIREMENTS

CIRCUIT
FREQUENCY
9 A
15 A
15 A
15 A
5 A
15 A
5 A
15 A
5 A
15 A
60 HZ
60 HZ
60 HZ
60 HZ
60 HZ
A wiring
diagram label
and the rating
label are
attached to
the back of
the range