Fisher & Paykel PROFESSIONAL RGV3-488 Installation Manual page 12

Hide thumbs Also See for PROFESSIONAL RGV3-488:
Table of Contents

Advertisement

WALL SURFACE
Non-combustible
Combustible
RANGE
30" models
36" models
48" models
Installations against non-combustible surfaces: you may install the range without a backguard or choose any of the three backguards.
z
Installations close to combustible surfaces (above the cooking surface): without a backguard, there must be a min. 6" (152mm) clearance.
z
Installations immediately against combustible surfaces (above the cooking surface): you must purchase and fit the Wall Mount High
z
Backguard High Shelf and Angled Vent Trim.
Non-combustible surfaces: as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from non-combustible
z
materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6" (152mm) must be approved by the
local codes and/or by the local authority having jurisdiction.
12
BACKGUARD CONSIDERATIONS
NO BACKGUARD
NO BACKGUARD
RANGE MOUNT
LOW BACKGUARD
HIGH BACKGUARD, LOW SHELF
BGRV2-1230
BGRV2-1236
BGRV2-1248
BACKGUARD OPTIONS
max. 30"
(762mm)
CUSTOM BACKGUARD
made from non-combustible materials
min. 6"
(152mm)
HIGH THICK BACKGUARD
with angled trim
WALL MOUNT
HIGH BACKGUARD, HIGH SHELF
BGRV2-3030
BGRV2-3036
BGRV2-3048
max. 1/2"
(13mm)
LOW THIN BACKGUARD
WALL MOUNT
BGRV3-3030H
BGRV3-3036H
BGRV3-3048H
Note: Backguards can be purchased separately. All
ranges come fitted with an Integral Vent Trim only.
For more information on Backguard installation, refer to
the separate instructions provided with your backguard.
Backguard Installation Instructions can also be
downloaded from our website, www.fisherpaykel.com
HIGH THIN BACKGUARD
BACKGUARD WIDTH
INCHES
MM
29 7/8
759
35 7/8
911
47 7/8
1216