c)
The machine has undergone repairs that required the disconnecting of the generator from the
mechanical section of the machine.
Failing to perform the Home function, once any of the afore-mentioned conditions has occurred, may
result in an incorrect operation of the
travels toward the selected direction.
2) Before initiating travel, make sure that the Ignore Short Circuit (IZR) function is inactive.
Error messages:
Not all home positions have been reached: The machine has failed to reach all home positions. This
error occurs, if one of the limiting switches is damaged, or one of the cases specified in item 2.1.8
[General error messages concerning travel] has occurred.

2.1.6 Travel to characteristic points

Intended use: This function enables automatic travelling of the working bit of the machine toward a central
point of the machine working space.
Access path: Manual Mode [R] -> Travel -> Travel to characteristic point
Course of action:
o
The machine will travel, according to the set value.
The following keys are available, when this function is carried out:
[STOP]: Travel is stopped immediately. When the function is paused, the following options for further
actions will appear on the screen:
"
a.
[Fx]
"
b. [Fx]
Attention!!!
Before initiating travel, make sure that the Ignore Short Circuit (IZR) function is inactive.

2.1.7 Travel to the beginning of program

Intended use: This function enables automatic travelling of working bit of the machine toward the datum point
of a selected working program.
Access path: Manual Mode [R] -> Travel -> To the beginning of program
Course of action:
o
The machine will travel, according to the set value.
The following keys are available, when this function is carried out:
[STOP]: Travel is stopped immediately. When the function is paused, the following options for further
actions will appear on the screen:
"
a.
[Fx]
"
b. [Fx]
Error messages:
If the function is inactive (the machine has not travelled to the beginning of program) and the machine
has automatically returned to the main menu of the manual working mode, see item 3.3.1 [Error
Messages].
Attention!!!
Before initiating travel, make sure that the Ignore Short Circuit (IZR) function is inactive.

2.1.8 General error messages regarding travels

Travel can be stopped immediately, if an emergency situation occurs. Look below at a list of potential errors:
Short circuit: The working bit has come into contact with the table (workpiece), during travel. It is
possible to deactivate short circuit detection, by activating the Ignore Short Circuit function (the [IZR]
key), prior to commencing travel.
Attempting to exceed physical or base coordinates.
"
Continue
: Travel will continue;
"
Abort
: Travel will be stopped.
"
Continue
: Travel will continue;
"
Abort
: Travel will be stopped.
"
travel to a characteristic point
"
function and locking of manual