f) Use a blowing system that eliminates vapours from above the tank, or a spot extractor
vapours must be directed outside the working room. The extracting system must
be efficient, in order to eliminate any condensation of the dielectric fluid in conduits, or
possible isolated water pools, as that can pose a fire hazard.
g) It is absolutely forbidden to operate the machine without supervision.
Protection measures:
a) At least two carbon-dioxide extinguishers or halide fire extinguishers within easy
reach, if there is fire.
b) A fire blanket.
Fire extinguishing procedure:
a) Disconnect supply voltage (press the STOP ENERGY button).
b) Eliminate flames.
c) Use a fire extinguisher (Attention!!! Do not aim the stream of gas directly at the
petroleum surface, as it can result in splashing of the dielectric fluid).
d) Call external services and act adequately to the course of events.
14. INSPECTIONS AND MAINTENANCE OF THE MACHINE
The machine must undergo period inspections, carried out at an authorised service
workshop of the manufacturer
Responsibilities of the user:
a) Keep the machine clean;
b) Change filters after every 200 hours of operation;
c) Change seals in the lids of both filter housings, as necessary;
d) Refill petroleum systematically, up to the level marked on the tank;
e) Clean the tank every 12 months;
f) Prevent petroleum from spilling outside the machine and form pools; similarly, make
sure there is not post-erosion silt deposited in the tank;
g) All systems and guards must be checked, before each operation;
h) The power network supplying the machine must be efficient (check the technical
condition of connections and neutral points
i) Report all noticed malfunctions or unexpected events to the authorised service
workshop of the manufacturer.
© Zakład Automatyki Przemysłowej B. P.
every 2 years.
PE);
10