Table 2-9 Css 11503 To Dc Power Source Cabling - Cisco 11500 Series Hardware Installation Manual

Content services switch
Table of Contents

Advertisement

Connecting the Power Cord
3.
Before installing a wire, ensure that the polarity of the DC connections is
Warning
correct. Reversed polarity causes damage to the DC power supply and can
create a dangerous shock hazard.
Do not consolidate the end of a conductor by soft soldering prior to installation.
4.
When installing the wires, always connect the ground wire first. When
Warning
disconnecting the wires, always disconnect the ground wire last.
5.
6.
Table 2-9
CSS 11503
+
Warning
The proper wiring sequence is ground to ground, positive to positive, and
negative to negative. The ground wire should always be connected first and
disconnected last.
Cisco 11500 Series Content Services Switch Hardware Installation Guide
2-30
Using a flat-head screwdriver, loosen the captive screws on the three DC
connectors (labeled from left to right, –, +, and
Install the wires into the appropriate connector. Make sure that the
non-insulated part of each wire is 9 mm (0.35 inches) in length.
Tighten the captive screws to 5 to 7 inch-pounds (0.6 to 0.8 Nm) of torque to
secure the wires in the connectors. Ensure that the wires are held firmly in
place.
Install the wires to the DC power source.
For the proper power cable wiring between the CSS 11503 and DC power
source, see
Table
2-9.
CSS 11503 to DC Power Source Cabling
(Ground)
DC Power Source
(Ground)
+
Chapter 2
Cabling the CSS
, respectively).
78-13884-03

Advertisement

Table of Contents
loading