Configuring Interfaces on the PRP
To comply with Telcordia GR-1089 NEBS standard for electromagnetic
Note
compatibility and safety, connect all console, auxiliary, Ethernet, and
BITS (PRP2) interfaces only to intrabuilding or nonexposed wiring or cabling.
The intrabuilding cable must be shielded and the shield must be grounded at both
ends.
Figure 10
shows a PRP RJ-45 receptacle and cable connectors. The RJ-45
connection does not require an external transceiver. The RJ-45 connection
requires Category 5 unshielded twisted-pair (UTP) cables, which are not available
from Cisco Systems, but are available from commercial cable vendors.
Table 3
lists the pinout for the RJ-45 receptacle.
Figure 10
RJ-45 Receptacle and Plug (Horizontal Orientation)
8 7 6 5 4 3 2 1
1
2
1
RJ-45 receptacle
2
Category 5 UTP cable with plug
The ports labeled Ethernet, 10BASE-T, Token Ring, Console, and AUX are safety
Warning
extra-low voltage (SELV) circuits. SELV circuits should only be connected to
other SELV circuits. Because the BRI circuits are treated like
telephone-network voltage, avoid connecting the SELV circuit to the telephone
network voltage (TNV) circuits.
Performance Route Processor Installation and Configuration Guide
45
OL-11656-01