Standard Model - Omron S8VS-24024A -F Series Manual

Switch mode power supply. indication monitor for visualization of operating status for even greater maintenance efficiency
Hide thumbs Also See for S8VS-24024A -F Series:
Table of Contents

Advertisement

480-W Models

Standard Model

S8VS-48024
1
2
Models with Indication Monitor
S8VS-48024@
1
2
9
10
16
15
14
13
12
11
Note: The illustration shows the S8VS-48024A model.
* The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
No.
1
2
3
4
5
6
4
5
3
7
6
7
8
8
4
5
9
3
10
11
12
13
14
15,
16
*1. The fuse is located on the (L) side. It is NOT user replaceable.
*2. This is the protective earth terminal specified in the safety standards.
*3. S8VS-48024A/B only.
*4. S8VS-48024A only.
*5. S8VS-48024B only.
Name
AC Input terminals
Connect the input lines to these
(L), (N)
terminals. *1
Protective Earth
Connect the ground line to this
terminal (PE)
terminal. *2
DC Output terminals
Connect the load lines to these
(−V), (+V)
terminals.
Output indicator
Lights while a direct current (DC)
(DC ON: Green)
output is ON.
Output voltage adjuster
Use to adjust the voltage.
(V.ADJ)
Indicates the measurement or set
Main display (Red) *3
value.
Lights up when the output voltage is
V
indicated. Blinks during setup of
undervoltage alarm value.
Lights up during indication of output
A
current.
Lights up during indication of peak
Apk
hold current.
Operation
Lights up during indication of
indicator
maintenance forecast monitor.
(Orange) *3
Yrs
Blinks during setup of maintenance
forecast monitor setting. (S8VS-
48024A)
Lights up during indication of total
run time monitor. Blinks during setup
kh
of total run time monitor. (S8VS-
48024B)
Use the Mode Key to change the
Mode Key *3
indicated parameter or reset the
peak hold current value.
Use the Up Key to change to the
Up Key *3
setting mode or to increase the set
value.
Use the Down Key to change to the
Down Key *3
setting mode or to decrease the set
value.
Undervoltage
output terminal
(DC Low)
Output when a drop is detected in
(Emitter side)
the output voltage (voltage drop =
Undervoltage
transistor OFF).
output terminal
(DC Low)
(Collector side)
Maintenance
Forecast
Output when the set value for
output terminal
maintenance is reached (transistor
(Yrs) *4
OFF).
Alarm
(Emitter side)
outputs
Total run time
*3
output terminal
Output when the set value for total
(kh) *5
run time is reached (transistor OFF).
(Emitter side)
Maintenance
Forecast
Output when the set value for
output terminal
maintenance is reached (transistor
(Yrs) *4
OFF).
(Collector side)
Total run time
output terminal
Output when the set value for total
(kh) *5
run time is reached (transistor OFF).
(Collector side)
NC (Not connected)
Always ground this terminal.
S8VS
Function
17