Quick Links

Switch Mode Power Supply
S8VT
Natural Cooling Three-phase Power
Supply Range from 5A up to 40A
with Output Voltage of 24VDC
• 3 phase 400 to 500 VAC
• 5, 10, 20 and 40 A; 24 VDC output
• Higher stability, lower ripple and noise level
• Mounts to DIN rail
• Fuses protection included
• Natural ventilation
• UL60950 (CSA22.2-60950), UL508 listing
in addition to the CE mark
• Conform to EN61000-3-2
• Parallel & serial operation possible
Model Number Structure
Model Number Legend
S8VT -
1
2
1. Input Voltage
F: 400 to 500 VAC 3-phase

Ordering Information

List of Models
Input voltage
120 W
240 W
400 to 500 VAC
3-phase
480 W
960 W
120/240/480/960 W Models
24 E
3
2. Power Rating
120: 120 W
240: 240 W
480: 480 W
960: 960 W
Power rating
24 V
24 V
24 V
24 V
Output voltage
Output current
5 A
10 A
20 A
40 A
3. Output Voltage
24: 24 V
Model number
S8VT-F12024E
S8VT-F24024E
S8VT-F48024E
S8VT-F96024E
1

Advertisement

loading

Summary of Contents for Omron S8VT

  • Page 1: Ordering Information

    Supply Range from 5A up to 40A with Output Voltage of 24VDC • 3 phase 400 to 500 VAC • 5, 10, 20 and 40 A; 24 VDC output • Higher stability, lower ripple and noise level • Mounts to DIN rail •...
  • Page 2: Specifications

    Weight 0.71 kg 0.91 kg 1.8 kg 3.3 kg *1) UL approval up to 600 VDC *2) MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices.
  • Page 3: Engineering Data

    When the output current rises above between 105 to If output voltage exceed the rated voltage more than 25% (50% at 130% (105 to 120% for the 40 A model) of the rated current, the maximum) by some reason, then the output voltage will be protection function is triggered, decreasing the output voltage.
  • Page 4 S8VT Dimensions and Nomenclature Note: All dimensions shown are in millimeters. S8VT-F12024E S8VT-F24024E S8VT-F48024E S8VT-F96024E 1. AC input L1 5. LED Vout ok 9. Vout - 2. AC input L2 6. Vadj. Trim 10.Vout - 3. AC input L3 7. Vout + 11.DIN-rail clip...
  • Page 5 Power Supplies to the same value. Also, make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will have no voltage drop difference. Parallel connection is only permissible with ambient temperature from -10°C to +50°C.
  • Page 6: Safety Precautions

    !WARNING Indicates information that, if ignored, could possibly result in loss of life or seriously injury. Indicates information that, if ignored, could result in relatively serious or minor injury, damage to the product, or faulty !Caution operation.

This manual is also suitable for:

S8vt-f12024eS8vt-f24024eS8vt-f48024eS8vt-f96024e