6.4.3 Humidity sensor connection 0...10 V
• Stand-aloneconfigurationCFG = 3,
• ParallelconfigurationasmasterCFG = 8.
3 = Sensor power supply
(if fitted)
4 = V+
5 = GND
6.4.4 External proportional humidistat connection with signal 0...10 V
• Stand-aloneconfigurationCFG = 1,
• ParallelconfigurationasmasterCFG = 6.

6.4.5 ON/OFF connection with humidistat or external contact

• Stand-aloneconfigurationCFG = 0;
• ParallelconfigurationasmasterCFG = 5.
924EHUCE4.00 - Mistral Humidifier
1 2 3 4 5 6 7
Fig. 21. Humidity sensor connection 0...10 V
4 = V+
5 = GND
1 2 3 4 5 6 7
Fig. 22. External proportional regulator connection with signal 0...10 V
ON/OFF
1
2 3 4 5 6 7
Fig. 23. ON/OFF connection with humidistat or external contact
RH
0...10 V
0...10 V