HighPressure Humidifier - Constant Pressure
Please before using your equipment read this guide carefully, by noting all the precautions and safety
instructions reported in it. Keep your equipment in good operative conditions.
Familiarize with the working and security instructions related to the operation of your apparatus before
trying to make it function. Keep this guide and any other booklet provided with your apparatus to be able
to refer to them later.

1 Package content

The High Pressure Humidifier package is composed of:
The high pressure humidifier central unit
This user guide
The high pressure pump user manual
The inverter user manual
A yellow cap for the pump oil to replace the red one (to be used only for transport)

2 Safety measures

People who are not familiar with this type of apparatus or which did not read attentively this guide do not
have to be authorized to use the humidifier.
The humidifier is designed to be used on alternative 220Vac 50/60 Hz only. Do not try to connect it to a
different type of supply. Check that the sector supply voltage corresponds to that of the apparatus.
The humidifier must always be switched-off before any maintenance operations.
All operations of maintenance and repairs must be carried out by the manufacturer, his technical service
or any other qualified personnel to avoid any problem.
Do not cover any opening of the humidifier and do not insert objects in the openings

2.1 Ground Connection

The first operation of each installation is the correct ground connection for the equipment, following the
safety regulations of the state and at the time when the equipment is installed.

2.2 Thermo-hygrometric conditions of the installation

Check that the environmental conditions of the place where the installation is carried out are always
compatible with the requirements of the product as indicated in this manual. ELSTEAM products cannot
be installed exposed to weather conditions or frost, unless different conditions explicitly expressed in
countersigned documents.

2.3 Electrical Connections

ELSTEAM equipment must be connected to the power supply by carefully following the local regulations
and the specifications on the plates of the equipment.
In particular, it is mandatory that the power supply lines have a correct section and are equipped with a
standard disconnecting switch with differential safety (life-saving device) capable of protecting the user
not only against the device, but also against the power lines installed.

2.4 Hydraulic Connections

ELSTEAM equipment needs to be connected to the water supply. Supply water shall comply with
microbiological requirements of the German Drinking Water Ordinance (TrinkwV). Only ELSTEAM HPN
DEMI humidifier complies with VDI6022 certification when using reverse osmosis water (not in contact
with drinking-water mains). Should the unit be installed using normal water the installer must use a VDI
6022 non return valve to be still compliant.
It is necessary to strictly comply with the local actives regulations (for installation) and make sure that
any breakages or water leaks deriving from the installation or from the units itself cannot cause damage
to the environment or to third parties. Do not install the equipment on passageways or over dangerous or
susceptible objects and always provide special drainage systems that can evacuate any spilled water
Elsteam S.r.l - via E.fermi, 496 - 21042 Caronno Pertusella (va) - Tel.+39 02 9659890 - Fax +39 02 96457007
E-mail: info@elsteam.it - Web: http://www.elsteam.com
21.1.EN
3

Advertisement

Table of Contents
loading

Table of Contents