- 2 - INSTALLATION
2.1 Lamp
We recommend that you use HPL750 230V-750W 3200°K with a base G9,5. Make sure that the lamp you
use is compatible with local voltage.If the lamp is operated with a voltage surpassing its nominal operating
voltage, it can be damaged or its service life reduced considerably.
2.2 Inserting o replacing the lamp
Please proceed as follows to replace the lamp (The lamp gets very hot during operation, so let it cool down
sufficiently before you attempt to dismount it!Lamps that have been damaged must be replaced immedi-
ately).
1. Disconnect power to the profiler before installing the lamp.
2. Unscrew the knobs lamp holder (fig.3).
3. Remove the lamp housing, substitute the lamp (fig.2).
4. Reposition the lamp housing and screw the its knobs.
Lamp
housing
2.3 Mounting
• Install the projector at a suitable location by means of the mounting bracket (3).
• Always additionally secure the projector with the safety rope from falling down. For this purpose, fasten
the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
• Adjust the projector and use the knob (4) to slightly release or tighten the locking mechanism of the
bracket if is necessary.
• Open the retaining clip and pull out the filter support (10).
• Insert the desired color filter into the filter support.
• Reinsert the filter support.