INSTALLATION

CAVITY HOUSING ASSEMBLY

NOTE: Left side panel has no hole for the water
manifold connections. The side panels are not
interchangeable and will not fit into the shelf/drain
unit if assembled otherwise.
1. Position core panel upright onto the right side
edge.
2. A. Partially insert the tabs from the left side panel
into the slots on the top left hand side of the
core panel.
B. Align and insert tabs from the rear core panel
into the slots of the left side panel.
C. Insert the front tab from core panel into open
slot on the left side panel. Confirm all tabs are
fully inserted into the adjacent slots. Left side
panel is now fully secured to the core panel.
3. Turn core panel assembly end over end so the
left side panel is on the bottom.
4. Slide pins from the hinged door panel into open
hinges on core panel.
5. A. Partially insert the tabs from the right side
panel into the slots on the top right hand
side of the core panel.
B. Align and insert tabs from the rear core
panel into the slots of the right side panel.
C. Insert the front tab from core panel into
open slot on the right side panel. Confirm all
tabs are fully inserted into the adjacent
slots. Right side panel is now fully secured
to the core panel.
Form No. HQTM-0206
C
Figure 4. Right Side Panel Assembly
Figure 5. Cavity Assembly
4
B
A
A
B
C