2 SYSTEM CONFIGURATION

2.4 Precautions for System Configuration

2 - 7
Downloaded from
ManualsNet.com
(1) The QJ71AS92 can be mounted in any slot of the base unit.
If the QJ71AS92 is mounted on an extension base unit (Q52B, Q55B) to which
the power supply module cannot be mounted, the power supply capacity may be
insufficient.
(2) The QJ71AS92 cannot be mounted on a remote I/O station in a
MELSECNET/H network system.
(3) The QJ71AS92 can use the slave addresses assigned to AS-i Ver.
2.11-compatible slaves by grouping them into A and B.
The other slaves
grouped into A and B because of the AS-i specifications. Assign them to the
slave addresses other than those used for group A and B.
*1: Check whether the slaves can be grouped or not by reference to the
manuals of the slaves used.
*2: Analog slave, AS-i Ver. 2.04-compatible I/O slave, etc.
(4) For Use with Q12PRH/Q25PRHCPU
(a) GX Configurator-AS connection
GX Configurator-AS cannot be used when accessing the
Q12PRH/Q25PRHCPU via an intelligent function module on an extension
base unit from GX Developer.
Connect a personal computer with a communication path indicated below.
1
2
search engine
2
*
than the AS-i Ver. 2.11-compatible I/O slaves cannot be
1
2
Direct connection to the CPU
Connection through an intelligent function module on the main base unit
(Through Ethernet module, MELSECNET/H module, or CC-Link module)
MELSEC-Q
1
*
Main base unit
Extension base unit
(GX Configurator-AS cannot be used.)
2 - 7