Copies of this instruction manual are available upon request. The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non-compliance with the instructions contained herein.
Page 5
5. Always unplug this appliance immediately after using. 6. Always unplug the appliance before cleaning and maintenance. WARNING! To reduce the risk of burns, electrocution, fire, or injury to persons: 1. The electric components must not come in contact with water. Check all cables regularly and call the aftersales service when any cable is in improper condition.
4. Do not sit on the footrest. 5. Do not lean against the headrest. 6. Do not step on the base. 7. Do not sit on the base. 8. Do not use the base as a foot support. NOTICE! 1. Never use any other cleansing method as described in chapter CLEANING AND ;...
4. INSTALLATION INSTRUCTIONS 4.1 Unpacking Open the top of the carton carefully. Do not use any sharp-edged objects; otherwise you can damage the upholstery. Do not lift the PLS but remove the top cover of the carton. Then you can pull up and remove the outer package. 4.2 Specifications The PDS product line includes the models PLS Basic, Comfort and XP.
5. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short-circuit, grounding reduces the risk of electric shock by providing a path of low resistance for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
6.3 Leg rests You can adjust the leg rests separately (independent of the back rest). When they are at the same height as the seat, they have reached their highest position. Given the horizontal position you can lower the leg rests up to 90 .
6.6 Height The horizontal working height can be adjusted from 49.5 cm to 84 cm (46 cm with Memory - boarding/alighting support option). You can increase the working height with the adjustable feet by max. 3 cm. The height adjustment is electrically- powered( all models).
6.8 Foot Control Panel (optional equipment) The optional FCP can be connected instead of the standard FCP. It is equipped with a right (R) and a left (L) foot switch unit and a central electronic unit. You find the diodes A1, A2, A3, A4, A5 and A6 on the central electronic unit. Save Without function Without function...
6.8.2 Loading of a position Press and hold R2 until diode A1 lights. Then press L1 or L2 until the saved position has been reached. 6.8.3 Initializing of the software If the saved memory positions are not loaded properly, you may have to re- initialize the software.
6.9.1 Heater control panel You can operate the heater using the 4 buttons ON/OFF/+/-. The setting of the heating power is indicated by a 10-level LED bar-diagram. The green LEDs 1-4 indicate low power/low temperatures. The yellow LEDs 5-7 indicate medium power/medium temperatures. ...
Page 14
1. Press and hold the OFF-button. 2. Press and release the ON-button. 3. Release the OFF-button and enter the Setting of the total operation period. You can set 10 levels from 10 to 100 minutes. The position of the single and illuminated LED - from the left to the right - indicates the level.
6.10 Rotation function You can rotate the seat of the PLS by 105 to the right or left. During treatment, always lock the desired adjustment using the lever which is located under the seat. Loose the lever to change the treatment position of the seat, then lock again. This function can be used only when the leg rests are not folded down by 90 .
7.1 Trouble shooting In case of any malfunction, please contact our service department. 8. TECHNICAL DATA Height 49.5 cm* to 84 cm Length max. 2.00 m Width (with/without arm rests 49/68 cm Max. working height/heel 1.24 m Inclination lying surface Lifting capacity 160 kg Inclination backrest...
9. AMBIENT CONDITIONS Environmental conditions for storage and transport Temperature ambient temperature -10°C to+50°C Atmospheric pressure 700 to 1060 hPa Relative humidity 20% to 90% non-condensing at +30 Ambient condition during use Temperature ambient temperature +5°C to +40°C Atmospheric pressure 700 to 1060 hPa Relative humidity 30% to 75% non-condensing at +30...
Upon delivery, it is necessary to check that the equipment has not been damaged during transportation and that the set of accessories is complete and in good condition. Claims must be filed within 8 days after the delivery of Gharieni PediSpa. Apart from the cases specified in the supply agreement, the guarantee is void when: The malfunctioning is attributable to the operator.
12. EC-DECLARATION OF CONFORMITY EC DECLARATION OF CONFORMITY Gharieni Group GmbH (Manufacturer) Gutenbergstraße 40; D-47443 Moers; Germany declare that the product (Type or model; name) is produced in accordance with the requirements specified in Low Voltage Directive (LVD) 2006/95/EG, Electromagnetic Compatibility 2004/108/EG,...
Page 20
THE PROPERTY RIGHTS OF THIS INSTRUCTION MANUAL ARE RESERVED. ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY. THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUTED Gharieni Group GmbH Gutenbergstraße 40 D – 47443 Moers...
Need help?
Do you have a question about the PLS Podo and is the answer not in the manual?
Questions and answers