GHARiENi MO 1 Instruction Manual

Spa table
Hide thumbs Also See for MO 1:
Table of Contents

Advertisement

➢ Phone:
➢ Fax:
➢ Customer service hotline:
➢ E-mail:
➢ Web:
Instruction Manual
Spa Table MO 1
Gharieni Group GmbH
Am Schürmannshütt 24
D - 47441 Moers
+49 (0)2841/88300-0
+49 (0)2841/88300-999
+49 (0)2841/88300-40
service@gharieni.de
www.gharieni.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MO 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GHARiENi MO 1

  • Page 1 Instruction Manual Spa Table MO 1 Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers ➢ Phone: +49 (0)2841/88300-0 ➢ Fax: +49 (0)2841/88300-999 ➢ Customer service hotline: +49 (0)2841/88300-40 ➢ E-mail: service@gharieni.de ➢ Web: www.gharieni.de...
  • Page 2: Table Of Contents

    3. Preliminary remarks .......................... 11 4. Intended use ............................11 5. Rating plate............................11 6. Delivery of the MO 1 ......................... 12 6.1 Installation ........................... 13 7. Upholstery of the MO 1 ........................13 8. Operation of the MO 1 ........................14 8.1 Characteristics ..........................
  • Page 3 17.2 Safety information ........................47 17.3 Control panel ..........................47 17.4 Trouble shooting ........................49 18. Initializing of the software of the MO 1 ..................50 19. Reset of the MO 1 ........................... 51 20. Cleaning and maintenance of the MO 1..................51 20.1 Cleaning and care of the PU upholstery ..................
  • Page 4 23.2 Ambient conditions for storing and transportation ..............63 23.3 Ambient conditions for operation ..................... 63 24. Technical data ..........................64 24.1 MO 1 ............................64 24.2 Triple Airback incl. heater ......................65 24.3 Vibro Wellness ........................... 65 24.4 Multimedia-Unit ........................65 25.
  • Page 5: Safety Information

    ➢ MAKE SURE THAT THIS MANUAL IS AVAILABLE TO ANYONE USING THE GHARIENI SPA TABLE MO 1 AND MAKE SURE THAT IT HAS BEEN READ AND UNDERSTOOD PRIOR TO USING THE DEVICE.
  • Page 6: Signal Words

    3. The technical data of your energy supplier must meet the data on the rating plate of the MO 1. 4. Do not modify the plug provided with the MO 1, if it will not fit the outlet, have a proper outlet installed by a qualified electrician (not covered by the guarantee).
  • Page 7 / or the plug yourself. RISK OF ELECTRIC SHOCK! 10. Always unplug the MO 1 if it is not used for a longer period of time. 11. Always disconnect the MO 1 from the mains before cleaning and / or maintenance.
  • Page 8 Do not use attachments / accessories not recommended by the manufacturer. 17. Never operate the MO 1 if it has a damaged cord or plug, if it is not working properly, if it has been damaged or if it has become wet.
  • Page 9 22. Do not allow any unauthorized person to operate the MO 1! 23. Use the MO 1 only on a level surface. 24. Do not place any objects or liquids on the MO 1. The appliance as well as the material can be damaged thereby. RISK OF ELECTRIC SHOCK! RISK OF DAMAGE! 25.
  • Page 10: General Information

    Ensure that there is sufficient free space for the MO 1 relevant to  its total length. Activate the lock function of the MO 1 to protect it from unauthorized  use and / or when you do not operate the MO 1 (look at chapter 9.2 EY LOCK...
  • Page 11: Preliminary Remarks

    ❖ The MO 1 is a versatile Spa Table. You can use it for e.g. cosmetic applications or full body massages in dry rooms. No other use is permitted: it will affect your guarantee rights.
  • Page 12: Delivery Of The Mo 1

    USE THE SPECIAL CARRYING SUPPORT HANDLES OPTIONALLY AS FOLLOWS 1. To move the MO 1 from the pallet, you must raise it by 8 - 10 cm first. Plug it in to do this. Then press the corresponding function button (first button-line of the manual control panel which is on one side on a suspension unit / s.
  • Page 13: Installation

    Now the MO 1 is ready for transport. You need 4 persons to move the MO 1 to its final site. If the ground is not even, you have to adjust the stability with the adjustment screw. After transportation, remove the carrying supports by unscrewing them.
  • Page 14: Operation Of The Mo 1

    (fig. similar: Colour and decor can vary depending on model) OFT UPHOLSTERY ❖ Optionally for an additional charge, it is possible to equip the MO 1 with an ergonomic soft upholstery (s. fig. below) made of PU. ❖ The extra soft upholstery is anatomically shaped.
  • Page 15: Characteristics

    8.1 Characteristics ❖ The MO 1 is a versatile Spa Table. You can use it for e.g. cosmetic applications or full body massages in dry rooms. ❖ The Gharieni MO 1 is a Spa Table which is equipped with up to six actuators.
  • Page 16: View

    ➢ The dedicated safety socket must be grounded properly and must meet the proper voltage (230 V AC). Before installation provide sufficient free space for the MO 1. The required minimum free space is 300*180 cm. 8.3 View (fig. similar: colour, decor, and upholstery may vary depending on the model)
  • Page 17: Headrest

    ❖ The cover plug of the nose slot is removable (s. fig. 4). ❖ Using a gel cushion (s. fig. 5, optional available at Gharieni) on the headrest upholstery can additionally support the face of the person to be treated (s. also chapter 22.13 G...
  • Page 18: Armrests

    ❖ Use the lever of the relevant side and press lightly to adjust the armrests freely; so the MO 1 is the optimal solution for back massages (s. fig. 6). As you can swivel the armrests you are closer to the head of the person to be treated when carrying out cosmetic or facial massages.
  • Page 19: Additional Locking Of The Armrests

    8.5.1 Additional locking of the armrests ❖ The armrests of the MO 1 can be locked additionally using the laterally- mounded locking button (s. fig. below). ❖ The additional lock enables higher stability and safety of the armrests. OCKING OF THE ARMRESTS 1.
  • Page 20: Leg Section

    RISK OF DAMAGE! 8.6 Leg section ❖ The leg section of the MO 1 can be adjusted fully electrically (s. chapter 9.6 DJUSTMENT OF THE LEG SECTION ❖ The leg section can be adjusted separately from the backrest using the manual control panel, the infrared remote control, and / or the foot control panel.
  • Page 21: Manual Control Panel

    (changing between level 1 and level 2) HIFT BUTTON ➢ S (resets the MO 1 to the basic position / in level 2 only) TART BUTTON ➢ S (you can set the hotkeys M1 - M8 to any desired position using...
  • Page 22 ➢ Push buttons for the adjustment of the (black WORK HEIGHT lettering / arrows). ➢ Push buttons for the saving and setting of the memory positions M1 und M2 (grey lettering). ➢ Push buttons for the adjustment of the (black BACKREST lettering / arrows).
  • Page 23: Key Lock

    ➢ In level 2 the LED above the shift button is on, in level 1 the LED is off. For safety reasons, the MO 1 moves only while pressing a button of the  MCP. When you stop pressing, all moving-operation will stop immediately.
  • Page 24: Adjustment Of The Work Height

    ❖ The horizontal work height of the MO 1 / standard upholstery is fully adjustable from approx. 50 cm up to 82 cm. ❖ The horizontal work height of the MO 1 / soft upholstery is fully adjustable from approx. 55 cm up to 87 cm; due to the thicker upholstery.
  • Page 25: Adjustment Of The Inclination Of The Seat Section

    9.7 Memory functions of the MCP ❖ The manual control panel of the MO 1 is equipped with eight memory positions (memory functions on level 2: M1 / M2 / M3 / M4 / M5 / M6 / M7 / M8).
  • Page 26: Extendable / Retractable Castors

    10. Extendable / Retractable castors The MO 1 is equipped with retractable castors. The retractable castors can be extended to change the site of the MO 1. The castors at the head side are pivoting, the castors at the foot side are fixed.
  • Page 27 MO 1. Do not extract the castors if any person is on the MO 1. Do not move the MO 1 on its castors if any person or load is on the MO 1; otherwise you damage the substructure or castors.
  • Page 28: Infrared Remote Control (Optional Equipment)

    4 actuators individually. Furthermore you can save and set max. 8 memory positions.  For safety reasons, the MO 1 moves only while pressing a button of the IRC. When you stop pressing, moving-operation...
  • Page 29: Foot Control Panel (Optional Equipment)

    ELECTING OF A PREVIOUSLY SAVED POSITION 1. Press the button. SHIFT 2. Press and hold the desired hotkey M1 - M8 until the position has M1 - M8 been reached. EY LOCK The IRC is equipped with a key-lock to protect it from unauthorized access. IRC: OCKING OF THE 1.
  • Page 30: Heater / Smart Thermo 2 (Optional Equipment)

    The parameters of the heater can be programmed and saved if desired. Check the current temperature before using the MO 1. Disconnect the MO 1 from the mains when it is not used for a longer period of time, e.g. during the night.
  • Page 31: Operating Of The Heater Smart Thermo 2

    Thermo function by pressing the OFF-button on the HCP to avoid heat accumulation. 4. Disconnect the MO 1 from the mains when it is not used for a longer period of time, e.g. during the night. WARNING! The cables of the models with Thermo and / or Vibro are between the upholstery and metal rack (depending on model).
  • Page 32 : -ON- UTTON : -OFF- UTTON EMPERATURE SELECTION BUTTON IME SELECTION BUTTON 2 blue LEDs 2 green LEDs 2 yellow LEDs 2 orange LEDs 2 red LEDs UTTON ❖ Press this button to switch on the Smart Thermo 2. 1. When the Smart Thermo 2 is switched on, it starts heating at the maximum heating / power level for 5 minutes (level 5: the 2 red LEDs (E) are illuminated).
  • Page 33 ➢ The heating / power level and the heating time of the Smart Thermo 2 can be changed at any time by using the corresponding buttons (s. description below: TEMPERATURE SELECTION BUTTON TIME SELECTION BUTTON UTTON ❖ Press this button to switch off the Smart Thermo 2. EMPERATURE SELECTION BUTTON ❖...
  • Page 34 Level 1 blue LEDs (A) Press button one time Level 2 green LEDs (B) Press button two times Level 3 yellow LEDs (C) Press button three times Level 4 orange LEDs (D) Press button four times Level 5 red LEDs (E) Press button five times ➢...
  • Page 35: Audio-Relax Headrest (Optional Accessory)

    4. Then select the TIME SELECTION BUTTON 5. Press this button repeatedly until three of the ten LEDs are illuminated (two blue LEDs and one green LED / s. fig. below). 6. Thereby one illuminated LED corresponds to a heating time of 10 minutes. 7.
  • Page 36: Vibro Wellness 10 (Optional Equipment)

    15. Vibro Wellness 10 (optional equipment) ❖ Vibro Wellness 10 is a pleasantly massaging vibration system. WARNING! 1. Do not use the option Smart-Thermo when your customer ➢ has got a pacemaker. ➢ is pregnant. ➢ is affected by thrombosis. ➢...
  • Page 37 (fig. similar / fig. serves as an example only) Fig. 12 Fig. 13 FF BUTTON NDIVIDUAL BUTTON ULSE MASSAGE BUTTON ULSE BUTTON ELLNESS MASSAGE BUTTON AVE BUTTON NTENSITY BUTTONS SHOULDER AREA BACK AREA NTENSITY BUTTONS FUSELAGE AREA BACK AREA NTENSITY BUTTONS PELVIC AREA BACK AREA NTENSITY BUTTONS...
  • Page 38: Operation

    15.2 Operation TARTING OF A MASSAGE ➢ You can start a massage by pressing the FOLLOWING BUTTONS FF BUTTON ❖ When the massage unit is operated for the first time, the setting INDIVIDUAL activated. ❖ All massage motors operate in the manufacturer`s setting (intensity level 2 / medium intensity).
  • Page 39 ➢ The levels are indicated on the LED-display as follows. Level 0 ( Level 1 Level 2 Level 3 LED O LED O ➢ When the lowest intensity (level 1) has been reached, press one of the (5) - (9) again to switch off the relevant motor. INTENSITY BUTTONS ➢...
  • Page 40: Triple Airback Incl. Heater (Optional Equipment)

    ❖ Please note: The will be restarted in the manufacturer´s WELLNESS MASSAGE setting. INISHING OF A MASSAGE ❖ A timer finishes a massage after 15 minutes automatically. ❖ If you want to stop the massage before, press the O (1). FF BUTTON The motor of the V becomes louder when operating the...
  • Page 41: Scope Of Delivery

    16.1 Scope of delivery ➢ Control unit on mounting panel ➢ 3 control buttons for adjusting of the air cushions ➢ 3 connection wires for the heating elements ➢ Heater control unit for Smart Thermo 2 (optional) 16.2 Installation information The grounding of the mounting panel is carried out via the permanently attached power cable.
  • Page 42 Air cushion 1 (lumbar spine) Air cushion 2 (lumbar spine) Air cushion 3 (thigh section) For deflating the air; air chambers are opened. ➢ Nevertheless you must apply direct manual pressure. For pumping the cushion. ❖ You can operate the heating system Smart Thermo 2 using the 4 buttons (s.
  • Page 43: Heating

    3. When the treatment is stopped prematurely, cancel the Smart- Thermo function by pressing the OFF-button on the HCP to avoid heat accumulation. 4. Disconnect the MO 1 from the mains when it is not used for a longer period of time, e.g. during the night. 16.5 Heating UTTON ❖...
  • Page 44: Programming

    UTTON ❖ Press this button to switch off the Smart Thermo 2. 16.5.1 Programming ❖ The heating / power level and the heating time of the Smart Thermo 2 can be changed at any time by using the corresponding buttons. EMPERATURE SELECTION BUTTON ❖...
  • Page 45 Level 1 blue LEDs (A) Press button one time Level 2 green LEDs (B) Press button two times Level 3 yellow LEDs (C) Press button three times Level 4 orange LEDs (D) Press button four times Level 5 red LEDs (E) Press button five times ➢...
  • Page 46: Multimedia-Sound-System (Optional Accessory)

    4. Then select the TIME SELECTION BUTTON 5. Press this button repeatedly until three of the ten LEDs are illuminated (two blue LEDs and one green LED / s. fig. below). 6. Thereby one illuminated LED corresponds to a heating time of 10 minutes. 7.
  • Page 47: Safety Information

    17.2 Safety information 1. Read the complete instructions. 2. Keep the MMU away from open flames, e.g. candles. 3. Do not expose the MMU to direct sunlight. 4. Do not press the control buttons too hard; otherwise you will damage the unit. 5.
  • Page 48 Play / Pause Stops music in iPhone mode. iPhone mode: press to play next track. Hold to speed up tracks. iPhone mode: press to play previous track. Hold to rewind. iPod/iPhone iPod / iPhone port. dock OMPATIBILITY I HONE iPod nano generation 8GB / 16 GB iPod touch generation 8 GB / 32 GB / 64 GB...
  • Page 49: Trouble Shooting

    The MMU is not plugged in properly. If the MMU is plugged in properly but you cannot The MMU cannot be switched on. operate it, please contact Gharieni Group GmbH. ➢ Unplug the MMU and then plug in again. The MMU e does not work at all.
  • Page 50: Initializing Of The Software Of The Mo 1

    ➢ Check proper condition and connection of the audio cable. 18. Initializing of the software of the MO 1 If a previously-saved position is no longer properly set, you may have to reinstall the software. To correct the differences of position, you have to carry out the...
  • Page 51: Reset Of The Mo 1

    ❖ Do not wear any arm and finger decoration such as rings or bracelets while carrying out any cleaning or maintenance operations. Otherwise you can scratch and damage the upholstery and / or the material of the base of the MO 1 unintentionally.
  • Page 52: Cleaning And Care Of The Pu Upholstery

    WARNING! Always ensure that water or other liquids cannot get into the housing and the fittings of the MO 1 or into the MCPs. RISK OF ELECTRIC SHOCK! RISK OF FIRE! 20.3 Cover of the upholstery ❖...
  • Page 53: Repair Of The Mo 1

    2. Repairs and modifications must be carried out by Gharieni Group GmbH or a person authorized by Gharieni Group GmbH. 3. The electrical installation of the room the MO 1 is installed in must meet the current legal regulations at the site where the MO 1 is operated.
  • Page 54: Malfunctions

    7. Malfunction of the software 7. Reset (s. chapter 19. R ESET OF THE MO 1) 8. Key lock is activated. 8. Unlock the key lock (s. chapter 9.2 EY LOCK INGLE MOTOR DOES NOT WORK 1. Motor-plug connected 1.
  • Page 55: Optional Equipment / Optional Accessories

    (s. below) please contact the Gharieni customer service. We will be glad to advise you! 22.1 Soft upholstery ❖ Optionally for an additional charge it is possible to equip the MO 1 with a high quality extra soft made of PU (polyurethane).
  • Page 56: Vibro Wellness 10

    ➢ s. also chapter 15. V IBRO WELLNESS 22.5 Audio Relax headrest ❖ An A for the MO 1 is also optionally available for an UDIO ELAX HEADREST additional charge. ❖ The A is equipped with integrated speakers and...
  • Page 57: Triple Airback

    Gharieni customer service. We will be glad to advise you! 22.11 Decorative surfaces ❖ D from our collection are optionally available. ECORATIVE SURFACES ❖ The colours white or wenge are included in the price of the MO 1. ❖ Other colours are optionally available for an additional charge.
  • Page 58: Models Including Electrical Castors

    ❖ An extendable holder for (magnifying) lamps made of stainless steel is available as an option for the MO 1; for an additional charge. Designed to fit the Flex LED magnifying lamp it simply disappears under the bed when not in use.
  • Page 59: Towels For Nose Slots (Disposable Cloths)

    EL CUSHIONS FOR NOSE SLOTS RTICLE NUMBER 22.16 Towels for nose slots (disposable cloths) ❖ D for the nose slot of the headrest of the MO 1 (s. fig. ISPOSABLE CLOTHS below) are optionally available for an additional charge. ❖ The...
  • Page 60: Protective Covers

    NECK REST  For detailed information regarding the right size and suitable version for the headrest of your Spa Table please contact the Gharieni customer service. We will be glad to advise you! (fig similar: colour and workmanship may vary depending on the model selected) 22.18 Protective covers...
  • Page 61: Protective Covers Made Of Pu

    ❖ Additionally, the covers are resilient, water- and oil-repellent, and washable up to 90  For detailed information regarding the right size and suitable version of the covers as well as the compatibility with your Spa Table please contact the Gharieni customer service. We will be glad to advise you!
  • Page 62: Ayurveda Cover

     For detailed information regarding the right size and suitable version of the cover as well as the compatibility with your Spa Table please contact the Gharieni customer service. We will be glad to advise you! (fig. similar: fig. serves as an example only)
  • Page 63: Protective Foot Cover

    23.1 Transport ❖ Carry the MO 1 by its base (supporting structure) during transport only. ❖ Never carry the MO 1 by its lying / sitting surface or its armrests during transport; otherwise you can damage the MO 1 seriously.
  • Page 64: Technical Data

    C (ambient temperature) Atmospheric pressure from 700 to 1060 hPa Relative humidity from 30% to 75% at +30 C non-condensing 24. Technical data 24.1 MO 1 ENERAL DATA Total Length 205 cm Total Width S 76 cm Total Width M...
  • Page 65: Triple Airback Incl. Heater

    Protection against solid and liquid materials IP X4 ❖ Technical modification reserved 24.2 Triple Airback incl. heater ENERAL Power of transformer (primary) 230 V AC / 50 Hz / 100 VA max. Power of transformer (secondary) 12 V AC / 100 VA max. Protection (primary) 1.6 AT (slow acting) ❖...
  • Page 66: Waste Management

    1. While unpacking, the packaging materials (polythene bags, polystyrene pieces, etc.) should be kept away from children and pets. CHOKING HAZARD! 2. Do not dispose of the MO 1 together with your domestic waste. Old and unused appliances must be send for disposal to the responsible recycling centre for electric appliances.
  • Page 67: Guarantee Provisions

    Claims must be filed within 8 days after the delivery of the Gharieni MO 1. Apart from the cases specified in the supply agreement, the guarantee is void when: The malfunctioning is attributable to the operator.
  • Page 68: Ec-Declaration Of Conformity

    27. EC-Declaration Of Conformity EC DECLARATION OF CONFORMITY Gharieni Group GmbH (Manufacturer) D-47443 Moers Gutenbergstr. 40 Germany declare that the product (Type or model, name) MO 1 2017 is produced in accordance with the requirement specified in Low Voltage Directive (LVD) 2014/35/EU...
  • Page 69: Status Of Edition

    RESERVED. ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY. THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUTED. Gharieni Group GmbH Am Schürmannshütt 24 D - 47441 Moers...

Table of Contents

Save PDF