Instruction Manual Spa Table MLE Neo Gharieni Group GmbH Gutenbergstraße 40 47443 Moers / Germany ➢ Phone: +49 (0)2841/88300-0 ➢ Fax: +49 (0)2841/88300-999 ➢ Distribution department: +49 (0)2841/88300-300 ➢ E-mail: service@gharieni.com ➢ Web: www.gharieni.com Empty area for entering the SERIAL NUMBER The serial number of the MLE is located on the rating plate (s.
Page 2
REFACE Dear Customer, we would like to thank you for purchasing this quality product as well as for the trust you have placed in us. Read the complete IM before you use the MLE for the first time. Reading the complete IM is essential for its proper and safe use and will help you to operate the MLE to your complete satisfaction.
Copies of this instruction manual are available upon request. ➢ The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to persons, animals or objects resulting from negligence or non-compliance with the instructions contained in this instruction manual.
1.1 Abbreviations ➢ GHARIENI SPA TABLE MLE NEO ➢ O PERATING ADVICE 1.2 Signal words DANGER! WARNING! indicates a hazardous indicates a hazardous situation which, if ignored, will result in situation which, if ignored, could result death or serious injury.
Page 7
6. The power supply cable shall not be placed below the MLE, except it is expressly permitted by the manufacturer. RISK OF ELECTRIC SHOCK! 7. The power cord must not be placed close to the actuators during connection or repositioning as it can be damaged while operating the actuators.
Page 8
WARNING! To reduce the risk of burns, electrocution, fire, or injury to persons: 1. Use a properly grounded socket with proper voltage (230 V AC) only. 2. The electric components must not meet water or other liquids. RISK OF ELECTRIC SHOCK! 3.
Page 9
SHOCK! RISK OF DAMAGE! 24. Any repairs and maintenance work must be carried out by qualified professionals authorized by the Gharieni Group GmbH only! RISK OF ELECTRIC SHOCK! RISK OF FIRE! 25. Do not use a steam cleaner for cleaning. RISK OF ELECTRIC SHOCK! 26.
Page 10
35. Children must not play with the MLE or its single components. 36. The MLE is not intended to be operated by persons with reduced physical, sensory, and mental capabilities or lack of experience or knowledge, unless they are supervised or instructed concerning the use of the MLE and do understand the danger resulting thereof.
Any other use is not permitted and will affect the warranty claims. ❖ The Gharieni Spa Table MLE is no medical device according to the medical devices act. ❖ The MLE is intended for indoor use only.
ELIVERY BY HARIENI ROUP If the MLE is delivered by Gharieni Group GmbH, the driver will help with the installation of the MLE and will also dispose of the packaging material and the special pallet. ELIVERY BY AN EXTERNAL FORWARDER If the MLE is delivered by an external forwarder, the MLE is normally only delivered.
Page 13
PACKAGING TAPES PPER CARDBOARD PECIAL PALLET HORT SIDES OF THE CARDBOARD 1. Cut the packaging tapes (A) with scissors and remove them. 2. D open the upper cardboard (B) but lift it carefully and vertically as a O NOT whole from the MLE and from the special pallet (C). For this purpose, you will need two persons (one person each on the short sides / D of the cardboard).
6. Assembly and transport of the MLE 6.1 Assembly The MLE is usually delivered fully assembled, so no assembly work is necessary. In exceptional cases, necessary assembly work will be carried out by the deliverer on site. Before installation, ensure that there is sufficient free space for the MLE corresponding to its total length.
CARRYING AIDS You also need the carrying aids (s. fig. above) to lift the MLE off the special pallet. The proper use of the carrying aids is described below in chapter 6.2.1. You need 4 persons to move or transport the MLE using the carrying aids. 6.2.1 Use of the carrying aids DANGER! After transport, while putting down the MLE, the power...
Page 16
Figures similar: All following figures serve as examples only. 1. To move the MLE from the special pallet, you must raise it first. Plug in the MLE to do this. Then press the corresponding push button of the hand control which is on one side on a suspension mechanism / button T 1, s.
Page 17
6. You need 4 persons to move the MLE to its final site. 7. It is essential to lift the MLE vertically off the special pallet using all four carrying aids. Otherwise you damage the adjustable feet. 8. Carry or transport the MLE using all four carrying aids only; otherwise you can damage the MLE irreparably.
NOTICE! One you have found a suitable place with enough space for the bed, remove the carrying aids and store them well for possible later transport! NOTICE! If the floor is not level, you must ensure proper stability of the MLE by adjusting the four adjustable feet.
Page 19
SE OF THE MECHANICALLY EXTENDABLE CASTORS Figures similar: All following figures serve as examples only. 1. Set the backrest in upright position (button T 2 of the hand control / s. fig. in chapter 11.1 HAND CONTROL (Fig. similar; fig. serves as an example only) 2.
Page 20
5. The castors are now extended. Before moving the MLE, unplug it, roll up the power cord properly and store the power cord in such a way, that you cannot roll over it when moving the MLE. Do not retract the castors unless the MLE stands at its desired site and you have checked that the cables are not located underneath the MLE.
7. Rating plate ❖ The rating plate is in the casing under the cover plate on the head side of the MLE (s. fig. 1 and fig. 2). ❖ The lever (B / fig. 2) is intended for the operation of the extendable / retractable castors (s.
Page 22
ECESS OF THE COVER PLATE AND THE CASING ATING PLATE If you wish to contact the Gharieni customer service regarding your Spa Table, we recommend taking a photo of the rating plate previously (e.g. using a mobile phone or a digital camera).
9. Upholstery of the MLE Neo ❖ The MLE Neo is equipped with a comfortable one-piece upholstery (s. fig. below). ❖ The inner material of the upholstery is made of high-quality foam material. ❖ The outer material of the upholstery is made of PU (polyurethane) and is available exclusively with a choco-coloured upholstery.
❖ The MLE is a versatile Spa Table. You can use it for e.g. cosmetic applications or full body massages in dry rooms. ❖ The Gharieni MLE is a Spa Table which is equipped with three actuators with which you can adjust the desired positions electrically using the hand control.
10.3 View (Fig. similar: Colour, decor and upholstery can vary depending on model) PPER CASING OWER CASING ➢ s. chapter 6.2.1 USE OF THE CARRYING AIDS EGREST ➢ Not adjustable. EAT AREA ➢ The of the seat area is electrically adjustable. INCLINATION ➢...
RMRESTS ➢ Pneumatically adjustable. ➢ s. chapter 10.4 and chapter 10.8 GAS SPRINGS ARMRESTS EAD SIDE ➢ On the head side under the cover there is the lever for extending the castors (see chapter 6.2.2 EXTENDABLE ) as well as the rating plate (see chapter RETRACTABLE CASTORS ) and the QR-Code (see chapter 8.
Page 31
For this purpose, the headrest is equipped with a separate upholstery part, which can be removed (s. fig. 6). ❖ Using a gel cushion (s. fig. 7, optionally available at Gharieni) on the headrest upholstery can additionally support the face of the person to be treated (see also chapter 17.1 G...
The N "D ” is optionally available for the MLE. ECKREST ENTALAX The N "D ” supports the cervical spine effectively and will ECKREST ENTALAX increase the comfort of lying significantly (see also chapter 17.3 N ECKREST “D ”). ENTALAX NOTICE! Do not lean, stand, or sit on the headrest;...
NOTICE! Do not lean, stand, knee or sit on the armrests; otherwise you can damage the armrests permanently. RISK OF DAMAGE! NOTICE! The maximum load capacity of the armrests is 25 kg. 11. Adjustments of the MLE ❖ The electrical adjustments of the MLE are made with a hand control. ❖...
Page 34
Button for adjustment of the WORKING HEIGHT Button for adjustment of the BACKREST Button for adjustment of the INCLINATION OF THE SEAT AREA This button has no function due to the configuration of the drive system. It is not possible to adjust the legrest. LOCK BUTTON ➢...
❖ Extracting of the adjustable feet (up to 3.00 cm) will increase the WORKING a bit. HEIGHT is the lowest position of the seat. ENTRY HEIGHT At this height, your customer has easy access to the MLE from the side. ➢ MLE Neo: approx. 54 cm / seat in horizontal position...
11.3 Adjustment of the backrest ❖ The inclination of the backrest can also be adjusted using the hand control. ❖ For the adjustment of the backrest press the corresponding button (T 2) (s. fig. in chapter 11.1). ❖ For the direction of movement, please note the arrow symbols and the number of dots above them on the hand control.
11.6 Locking function / locking button of the hand control ❖ The MLE is equipped with a function to protect against unauthorized LOCKING use. The actuators and drives lock automatically after 30 minutes of non-operation. The currently running heating cycle is not affected by this. ❖...
12. Heating system (optional equipment) ❖ The lying surface of MLE can be heated to maximize the treatment comfort. The heating system is a pre-programmed and fully automatic heating system which allows a comfortable operation. The intelligent heating system is integrated into the upholstery of the MLE and works with modern microprocessor technology.
Page 39
WARNING! 1. Do not use the option heating system if your customer ➢ has got a pacemaker. ➢ is pregnant. ➢ is affected by thrombosis. ➢ suffers from pain due to unknown reasons. 2. Apply to healthy people only. 3. If the treatment is ended prematurely, the heating system must be switched off by pressing the corresponding button on the hand control or on the optional foot control to prevent heat accumulation.
12.1 Operation ❖ The heating system is operated using the button (T 6) of the hand control. POWER ON ❖ Use this button to switch on the heating system. The heating system comes with three heat / power levels. To quickly heat up the bed‘s surface before starting treatment, we recommend setting the heating system to level 2;...
Page 41
There are three heat / power levels to choose from Visualization via Heating Heating level an LED (diode) output single impulse Push button Power on / for 0.3 seconds, 30 % button once level 1 interval 1 second double impulse, Push this lights up for 0.3 level 2...
13. Reset and Initialization If you notice that one or more bed functions can no longer be adjusted properly, the software of the MLE must be reinitialized. PLEASE PROCEED AS FOLLOWS Reset: Press the lower two buttons of the hand control (s. fig. below) simultaneously and hold them down for approx.
Page 43
The adjustment (initialization) must be carried out manually, i.e. each actuator must be moved individually to the end position. Please note that you keep the push buttons pressed for 2 - 3 seconds longer after reaching the end position. WARNING! This calibration (initializing) must be made manually, i.e.
14. Cleaning and maintenance of the MLE WARNING Always disconnect the MLE from the mains (unplug) before cleaning and maintenance. RISK OF ELECTRIC SHOCK! RISK OF FIRE! WARNING! Remove possible dust accumulation at the power plug, at the safety power socket and at all plug connectors regularly. RISK OF FIRE! WARNING! Always ensure that water or other liquids cannot get into the housing and the fittings of the MLE or into the hand control.
14.1 Cleaning and care of the polyurethane (PU) upholstery ❖ Clean the PU only with a soft cloth with a small amount of a detergent suitable for this material (also available from Gharieni: see chapter 18. UPHOLSTERY CARE AND CLEANING AGENTS NOTICE! PU can be cleaned with a small amount of a cleaning agent, which must be suitable for this material.
15. Malfunctions (possible causes and troubleshooting) ALFUNCTION OSSIBLE CAUSE ROUBLESHOOTING LL ACTUATORS DO NOT WORK 1. No connection to the mains. 1. Check the connection status. 2. The power supply cable is damaged. 2. Power supply cable must be replaced (please contact the customer service).
1. Always provide the serial number when contacting Gharieni customer service. 2. Repairs and modifications must be carried out by Gharieni Group GmbH or a person authorized by Gharieni Group GmbH. 3. If the electrical installation of the room the MLE is installed in, must meet the current legal regulations at the site where the MLE is operated.
17. Optionally available accessories For detailed information regarding the optionally available accessories (s. below) please contact our distribution department. Our team is happy to help! 17.1 Gel cushions for nose slots ❖ G for the headrest of the MLE are optionally available for an EL CUSHIONS additional charge.
17.2 Towels for nose slots (disposable cloths) ❖ D (s. fig. below) for the nose slot of the headrest of the MLE ISPOSABLE CLOTHS are optionally available for an additional charge. ❖ The are handy, hygienic, extra soft, and protect the DISPOSABLE CLOTHS upholstery of the headrest of your Spa Table.
For detailed information regarding the right size and suitable version for the headrest of your Spa Table please contact our distribution department. Our team is happy to help! 17.4 Protective covers 17.4.1 Protective covers made of terry ❖ P for your Spa Table are optionally ROTECTIVE COVERS MADE OF TERRY available for an additional charge.
17.4.2 Protective covers made of PU ❖ P (PU) for Spa Tables ROTECTIVE COVERS MADE OF POLYURETHANE (s. fig. below) are optional available for an additional charge. ❖ P PU serve the Spa Table as a second outer skin, ROTECTIVE COVERS MADE OF so to speak.
Page 52
: 49052 ROTECTIVE FOOT COVER ITEM NUMBER NOTICE! We recommend that you order the foot - protective cover directly with the purchase of your spa table. In this case, the counter Velcro is already attached to the spa table on delivery so that you can attach the foot cover easily and comfortably.
18. Upholstery care and cleaning agents ® 18.1 Mikrozid Sensitive (alcohol-free) ® ❖ We recommend Mikrozid Sensitive for gentle and thorough care and cleaning of the upholstery. ® ❖ Mikrozid Sensitive removes bacteria, fungi, and viruses (e.g. HBV, Rota, Vaccinia etc.). ®...
18.2 Skai cleaner ❖ For gentle and thorough care and cleaning of the artificial leather upholstery we additionally recommend Skai cleaner. ❖ Skai cleaner is available in a 200 ml spray bottle. ❖ Especially suitable for cleaning artificial leather. : 79427 KAI CLEANER TEM NUMBER...
19. Conditions for transport, storage, and operation 19.1 Transport (with castors / without castors) ❖ On flat surfaces, the MLE can be moved or transported using its castors (s. chapter 6.2.2 EXTENDABLE RETRACTABLE CASTORS ❖ On uneven surfaces, you must not use the castors of the MLE. In this case, lift the MLE during transport using the carrying aids only (s.
20. Technical data 20.1 MLE Neo ENERAL DATA Total Length 204 cm Total Width 85 cm Adjustable height approx. 54 cm - 88 cm Inclination of the headrest approx. +30°/ -30° Inclination of the backrest approx. 0° - 75° Inclination of the legrest approx.
20.3 Heating system Power supply 100 - 240 V ~ , 50 - 60 Hz : max. 1,6 A (at 90 V~ min.) Power consumption Input: approx. 144 W Output: approx. 120 W ❖ Subject to technical changes.
9. If suitable containers are not available at your residential area, dispose of these materials at a suitable municipal collection point for waste-recycling. 10. Receive more detailed information from your retailer, municipal facilities or: Gharieni Group GmbH ➢ Phone: +49 (0)2841/88300-0 ➢...
22. Warranty provisions The following warranty conditions apply to new goods worldwide: Gharieni Group GmbH grants on all spa tables of the MLE Neo series: → 10 years warranty on metal frames, → 5 years warranty on actuators and → 3 years warranty on other components.
THE OWNERSHIP RIGHTS TO THIS INSTRUCTION MANUAL ARE RESERVED. REPRODUCTION OR TRANSFER TO THIRD PARTIES IS PROHIBITED WITHOUT THE CONSENT OF GHARIENI GROUP GMBH. GHARIENI GROUP GMBH RESERVES THE RIGHT TO PROTECT ITS PROPERTY RIGHTS AND TO PROSECUTE ANY MISUSE. RODUCTION...
Need help?
Do you have a question about the MLE Neo and is the answer not in the manual?
Questions and answers