Page 1
Instruction Manual Spa Table MLR S ELECT 4 motors Fig. serves as an example only. Fig. similar: colour, upholstery and design may vary depending on model. Gharieni Group GmbH Gutenbergstraße 40 47443 Moers / Germany ➢ Phone: +49 (0)2841/88300-0 ➢ Fax: +49 (0)2841/88300-999 ➢...
Page 2
REFACE Dear customer, we would like to take this opportunity to thank you for purchasing our quality product and for the trust you have placed in us. Read the complete IM before you use the MLR S for the first time. ELECT Reading the complete IM is essential for its proper and safe use and will help you to operate the MLR S...
Index 1. Safety information ..........................5 1.1 Abbreviations ..........................6 1.2 Signal words ..........................6 1.3 Safety instructions ......................... 6 2. Intended Use ............................. 11 3. Scope of Delivery ..........................11 4. Preliminary remarks .......................... 12 5. Delivery and unpacking of the MLR S ..................
Page 4
11. Adjustments of the MLR S ....................... 37 ELECT 11.1 Hand control with memory function (optional) ................ 37 11.1.1 Adjustment of the working height ..................40 11.1.2 Adjustment of the backrest ....................41 11.1.3 Adjustment of the inclination of the seat section .............. 42 11.1.4 Adjustment of the Trendelenburg / anti-Trendelenburg function ........
Page 5
18.4 Neckrest “Dentalax” ........................78 18.5 Protective covers ........................79 18.5.1 Protective covers made of terry ..................79 18.5.2 Protective covers made of polyurethane (PU) ..............80 18.5.3 Protective foot cover ......................80 18.6 Holder for (magnifying) lamps ....................81 18.7 LED magnifying lamp Circle .......................
Copies of this instruction manual are available upon request. ➢ The Gharieni Group GmbH shall not be held responsible for any damages, direct or indirect, caused to people, animals or objects resulting from negligence or non-compliance with the instructions contained herein.
ELECT and/or its power supply (mains cable, mains plug). In case of unauthorised changes or manipulations, any warranty of the Gharieni Group GmbH is excluded. 5. Do not connect the MLR S to the mains if the Spa Table ELECT itself or the power cable or the plug are visibly damaged.
Page 8
8. Never try to repair the MLR S yourself. If the MLR S ELECT ELECT does not operate properly, please contact Gharieni Group GmbH or the dealer you purchased the MLR S at. Original spare parts ELECT should be used only.
Page 9
11. The cables of the models incl. the heating system and / or the Vibro Wellness 10 function are between the upholstery and the underframe. The upholstery may only be removed by persons authorized by Gharieni Group GmbH. 12. For MLR S with soft upholstery only: for long periods of ELECT use of the heating system (optional equipment), always keep some free space between the back and seat upholstery.
Page 10
Return the MLR S to an aftersales service ELECT authorized by Gharieni Group GmbH for examination and repair. 19. In case of defects of the spa table, contact customer service immediately. Use of the spa table must be discontinued until the problem has been solved to avoid further damage to property and persons.
Page 11
34. The MLR S must never be used to carry or transport persons ELECT or heavy loads. RISK OF INJURY! RISK OF DAMAGE! 35. While unpacking, the packaging materials should be kept away from children, pets, or persons with reduced mental capabilities. RISK OF INJURY! CHOKING HAZARD! 36.
❖ The Gharieni MLR S is a spa table. ELECT The Gharieni Spa Table MLR S is no medical device. ELECT ❖ The MLR S is a versatile Spa Table. You can use it for e.g. cosmetic ELECT applications or full body massages in dry rooms, etc.
ELIVERY BY THE HARIENI ROUP If the MLR S is delivered by the Gharieni Group GmbH, the driver will help ELECT with the installation of the MLR S and will also dispose of the packaging ELECT material and the special pallet.
ELIVERY BY AN EXTERNAL FORWARDER If the MLR S is delivered by an external forwarder, the MLR S ELECT ELECT normally delivered only (no help with the installation of the MLR S ELECT In this case, you must dispose of the packaging material and the special pallet on your own responsibility.
WARNING! The cables of the models incl. the heating system and / or the Vibro Wellness 10 function are between the upholstery and the underframe.The upholstery may only be removed by persons authorized by Gharieni Group GmbH! 6.2 Transport Transport of the MLR S...
CARRYING AIDS You need the carrying aids (s. fig. below) to lift the MLR S from the ELECT special pallet. The proper use of the carrying aids is described below in chapter 6.2.1. You need 4 persons to move or transport the MLR S using the carrying ELECT aids.
Page 17
Figures similar: all following figures serve as an example only. 1. To move the MLR Select from the special pallet, you must raise the MLR S first. Plug in the MLR Select to do this. Then press the ELECT corresponding push button of the hand control which is on one side on a suspension device / (button T 1, s.
Page 18
CARRYING AIDS PENINGS FOR THE CARRYING AIDS YING SURFACE 5. You need 4 persons to move the MLR S to its final site. ELECT 6. It is essential to lift the MLR S vertically off the special pallet using all ELECT four carrying aids.
Do not make the rating plate illegible! Do not remove the rating plate! Noncompliance will expire the guarantee! If you wish to contact the Gharieni customer service regarding your Spa Table, we recommend taking a photo of the rating plate previously (e.g.
ATING LATE (Figure similar, position might differ 8. QR-Code In case of service, you can scan the QR code using the OCR scan function of a suitable device (e.g. a smartphone). A form will then open via the Internet browser of your device, which already automatically contains the serial number of your MLR Select.
Page 21
QR-C (Figure similar, position might differ...
Page 22
Figure shows form that opens in the Internet browser of the device after the QR code is scanned.
Page 23
Figure shows form that opens in the Internet browser of the device after the QR code is scanned.
Page 24
Figure similar: option window for adding a file. Appearance may vary depending on the device and operating system.
9. Upholstery and design of the MLR S ELECT 9.1 Upholstery ❖ The MLR S is available in two upholstery variants (standard upholstery / ELECT soft upholstery / s. below). ❖ The upholstery of the MLR S is made of polyurethane (PU). ELECT (PU): TANDARD UPHOLSTERY MADE OF POLYURETHANE...
9.2 Versions of the base ❖ The MLR S is available with eight different versions of the base. ELECT MLR S ELECT ❖ The base of the MLR S consists of a solid plate with elegant ELECT wooden decor (s. fig. below). MLR S ELECT ❖...
Page 27
MLR S ELECT TATIC ❖ The base of the MLR S is intended to be bolted to the floor. ELECT TATIC This kind of installation offers spacious legroom and maximum stability (s. fig. below). MLR S ELECT VINTAGE ❖ The base of the MLR S in an exclusive metal-wood look offers ELECT VINTAGE extensive space for towels and everything else you need for your work...
❖ The entry height of the MLR S (soft upholstery) is approx. + 5 cm ELECT compared to the other upholstery variants due to the thicker upholstery. ❖ The Gharieni MLR S is a Spa Table with four, five or six actuators ELECT (s. chapter 10.2 M...
ELECT 350 kg. ❖ The maximum load capacity of the armrests is 25 kg. 10.2 Model variants / Number of actuators ❖ The Spa Tables of the Gharieni MLR S series are available in four various ELECT widths: S MALL...
10.2.1 MLR S / 4 actuators: ELECT MLR S ELECT ACTUATORS Electrical adjustment of the WORKING HEIGHT 2 lifting Electrical adjustment of the TRENDELENBURG columns ANTI TRENDELENBURG FUNCTION Actuator 1 Electrical adjustment of the BACKREST Electrical adjustment of the INCLINATION OF THE SEAT Actuator 2 : adjustable by the electrically adjustable SECTION...
10.4 View (example: MLR S ELECT Fig. similar: colour, design and equipment may vary depending on model. EIGHT ADJUSTMENT INCLINATION ADJUSTMENT ➢ s. chapter 11.1.1 resp. chapter 11.2.1 A DJUSTMENT OF THE WORKING HEIGHT ➢ s. chapter 11.1.4 resp. chapter 11.2.4 A DJUSTMENT OF THE RENDELENBURG RENDELENBURG FUNCTION...
YING SURFACE DIVIDED INTO a. Electrically adjustable backrest ➢ s. chapter 10.9 B and chapter 11.1.2 resp. chapter ACKREST 11.2.2 A DJUSTMENT OF THE BACKREST b. Knee bend (inclination of the seat section) ➢ The of the seat section is adjustable by the INCLINATION electrically adjustable KNEE BEND...
10.6 Headrest WARNING! Do not carry out any physical force to the headrest, regardless of the setting of the lying surface. Non-compliance can cause permanent damage to the construction of the MLR Select. RISK OF TIPPING! RISK OF DISINTEGRATION! RISK OF INJURY! The headrest is freely and manually adjustable (s.
(s. below: fig. 4). ❖ Using a gel cushion (s. fig. 5, optionally available at Gharieni) on the headrest upholstery can additionally support the face of the person to be treated (see also chapter 18.1 G...
Both face supports of the dual headrest have a nose opening. To obtain the nose opening on the round face support, please remove the separate oval upholstery part. ➢ see also chapter 18.1 HEADRESTS "D ” is optionally available for the MLR S NECKREST ENTALAX ELECT...
. 10 Fig similar: figures serve as an example only. NOTICE! Swivel the armrests without load only! Do not lean, stand, knee, or sit on the armrests; otherwise you can damage the armrests permanently. RISK OF DAMAGE! NOTICE! The maximum load capacity of the armrests is 25 kg. RISK OF DAMAGE! 10.7.1 Additional locking of the armrests ❖...
NOTICE! The additional lock must be released to adjust the armrests using the respective levers (s. chapter 10.7 A ). Otherwise the RMRESTS construction and the mechanics of the armrests can be damaged permanently. RISK OF DAMAGE! 10.8 Legrest The legrest is not adjustable. 10.9 Backrest ❖...
11. Adjustments of the MLR S ELECT ❖ The electrical adjustments of the MLR S are carried out using a hand ELECT control, an optional foot control or an optional foot control with Bluetooth. ❖ The pneumatic adjustments of the MLR S (armrests / headrest) ELECT are carried out using a gas spring using a lever.
Page 39
Button for adjustment of the WORKING HEIGHT Button for adjustment of the BACKREST Button for adjustment of the (seat area) INCLINATION Button for adjustment of the T RENDELENBURG ANTI TRENDELENBURG FUNCTION PROGRAM BUTTON P ➢ P1 moves the bed to the fixed PROGRAM BUTTON entry position.
Page 40
PROGRAM BUTTON P ➢ P P4 moves the bed to the fixed ROGRAM BUTTON massage position. ➢ The massage position cannot be changed. MEMORY BUTTON M ➢ M1 is used to save and recall the first MEMORY BUTTON individually adjusted and saved position. EMORY BUTTON M T 10 ➢...
YMBOLS FOR THE DOUBLE TAP SYSTEM ❖ The working height, backrest, inclination of the seat area and Trendelenburg / anti-Trendelenburg function (buttons T 1 - T 4) are adjusted using the double-tap system. ❖ This serves for safety. A movement associated with danger is made consciously by this.
is the lowest position of the seat / seat section. ENTRY HEIGHT At this height, your customer has easy access to the MLR S from the side. ELECT ➢ MLR S = approx. 61 cm / ELECT STATIC WOOD VINTAGE ELLIPSE seat (seat section) in horizontal position ➢...
11.1.3 Adjustment of the inclination of the seat section ❖ Via the electrically adjustable knee bend the inclination of the seat section (thigh section to knee bend section) can also be adjusted using the hand control. ❖ For adjustment of the inclination of the seat section press the corresponding button (T 3);...
11.1.5 Memory functions of the hand control ❖ In addition to four pre-set treatment positions, the MLR Select hand control has two individual memory positions (memory positions: M 1 / M 2). ❖ The memory function saves the treatment positions you wish to use and simplifies your work processes.
11.1.6 Locking function of the hand control with memory function ❖ The MLR Select is equipped with a of the hand control to LOCKING FUNCTION protect the spa table from unauthorized use. ❖ By default, no automatic locking is set. You can decide for yourself whether to change this.
Page 46
Example: 30 minutes is set as the automatic locking time. You want to change to the automatic locking time 60 minutes. Press the corresponding buttons simultaneously and keep them pressed for approx. 6 seconds until feedback about the now set automatic locking time 60 minutes is given through flashing of all LEDs of the hand control and beeps.
UNLOCKING THE DRIVES MANUALLY 1. To unlock the drives, press the button (T 11) LOCK on the hand control twice in quick succession (double-tap) and keep it pressed for about 2 seconds. 2. The successful unlocking is confirmed by an acoustic signal and the LED above the button on the hand control is switched off.
Page 48
By simply pressing a button and keeping it pressed, a movement is made upwards. By pressing a button twice (double-tap system) and keeping it pressed, a movement is made in the opposite direction. De-activation of the lock function also works with the double-tap system. Button for adjustment of the WORKING HEIGHT Button for adjustment of the...
11.2.1 Adjustment of the working height ❖ For adjustment of the press the corresponding button WORKING HEIGHT (T 1, s. fig. in chapter 11.2 HAND CONTROL WITHOUT MEMORY FUNCTION ❖ For the direction of movement, please note the arrow symbols and the number of dots above them on the hand control.
11.2.2 Adjustment of the backrest ❖ The inclination of the backrest can also be adjusted using the hand control. ❖ For adjustment of the backrest press the corresponding button (T 2, s. fig. in chapter 11.2 HAND CONTROL WITHOUT MEMORY FUNCTION ❖...
11.2.4 Adjustment of the Trendelenburg / anti-Trendelenburg function ❖ For adjustment of the inclination of the lying surface press the corresponding button (T 4, s. fig. in chapter 11.2 HAND CONTROL WITHOUT MEMORY FUNCTION ❖ For the direction of movement, please note the arrow symbols and the number of dots above them on the hand control.
11.2.5 Locking function / lock button of the hand control without memory function ❖ The MLR S is equipped with a LOCKING function to protect against ELECT unauthorized use. The actuators and drives lock automatically after 30 minutes of non-operation. The currently running heating cycle is not affected by this.
12. Foot control (optional equipment) ❖ The foot control (see illustrations) can be connected in addition to the hand control and enables the control of the basic functions, the storage and recall of individually stored memory positions M 1 and M 2, the recall of the permanently stored entry position as well as the operation of the locking function and the optional heating system.
Page 54
FOOT CONTROL LEFT FOOT CONTROL IGHT FOOT CONTROL LEFT WORKING HEIGHT DOWN BACKREST DOWN FOOT CONTROL IGHT (seat area): INCLINATION DOWN TRENDELENBURG ANTI TRENDELENBURG FUNCTION...
Page 55
LEFT PART AND RIGHT PART M 1: EMORY OSITION ➢ Saving the memory position: Left part of the foot control, press pedal 2 and right part of the foot control, press pedal 3 simultaneously twice (double-tap system) and keep them pressed until an acoustic signal confirms the successful saving.
Page 56
NOTICE! For safety reasons, the bed only moves while you are pressing one pedal or more on the optional foot control. When you release it, the movement stops immediately. To raise the bed, for example, you must press pedal 1 once and hold it down. To lower it, you must press the pedal twice and hold it down.
12.1 Foot control with Bluetooth (optional equipment) ❖ A foot control with Bluetooth can be connected as an option in addition to the hand control. ❖ The foot control enables the adjustment of the basic functions and the approach of the two fixed positions P1 to P4. In addition, the heating system can be operated, the bed can be locked and unlocked, and the bed software can be reset.
Page 58
NOTICE! To switch on the heating system with the first heating level, to change to the next heating level or to switch off the heating system, the buttons of the Bluetooth foot control must be held down for approx. one second. LEFT PART OF THE FOOT CONTROL WORKING HEIGHT DOWN...
Page 59
LEFT AND RIGHT PART OF THE FOOT CONTROL ➢ Press the left part of the foot control, button 1 and the right part of the foot control, button 3 simultaneously once (single tap) and keep them (Entry pressed until the position is reached. position) THE ENTRY POSITION CANNOT BE CHANGED ➢...
13. Heating system (optional equipment) ❖ The heating system is a pre-programmed and fully automatic heating system which allows a comfortable operation. The heating system is integrated into the upholstery of the MLR S ELECT works with modern microprocessor technology. The heating system is optionally available for an additional charge.
Page 61
ELECT influence of alcohol or drugs. WARNING! The cables of the models incl. the heating system are between the upholstery and the underframe (depending on model). The upholstery may only be removed by persons authorized by Gharieni Group GmbH!
13.1 Operation ❖ The heating system is operated using the button T 12 of the hand control with memory function resp. button T 6 of the hand control without memory function. ❖ For operation of the heating system using the optional foot control or the foot control with Bluetooth, see chapter 12.
Page 63
There are three heat / power levels to choose from Visualization via Heating Heating level LED (diode) output single impulse Push button Power on / for 0.3 seconds, 30 % button once level 1 interval 1 second double impulse, Push this lights up for 0.3 level 2 60 %...
Page 64
For operation with the optional foot control and with the optional foot control with Bluetooth, you also have a choice of three heat / power levels: Visualization via Heating Heating level LED (diode) output Pedals / single impulse Push pedals / Power on / buttons for 0.3 seconds,...
WARNING! The cables of the models incl. the Vibro Wellness 10 function are between the upholstery and the underframe. The upholstery may only be removed by persons authorized by Gharieni Group GmbH...
14.1 Hand control ❖ The 10 motors of the V 10 function are installed in different IBRO ELLNESS sections of the lying surface (s. fig. 8 / below). ❖ Use the associated hand control (s. fig. 9 / below) to activate the individual sections in pairs.
NTENSITY BUTTONS LEG AREA NTENSITY BUTTONS CALF AREA FOOT AREA Button to change the of the SPEED PULSE MASSAGE PROGRAMME (three levels). WELLNESS MASSAGE PROGRAMME 14.2 Operation OW TO START A MASSAGE ➢ You can start a massage by pressing the FOLLOWING BUTTONS FF BUTTON ❖...
Page 68
(5-9) NTENSITY BUTTONS ❖ Pressing one of these buttons sets the relevant massage motor to intensity level 1. Please note: Doing so will overwrite a previously-set individual setting (s. below: INDIVIDUAL SETTING (2): NDIVIDUAL SETTING ➢ Start the massage by pressing the (2).
Page 69
➢ You can select three levels of intensity with the (5) -(9). INTENSITY BUTTONS Please note: The will be restarted in the manufacturer´s setting. PULSE MASSAGE (4): ELLNESS MASSAGE ➢ Press the W (4) to start the massage with the ELLNESS MASSAGE AVE BUTTON...
15. Reset If a previously saved position is no longer properly set, you may have to reset the software of the MLR S . To correct the differences of position, you must ELECT carry out the following steps. NOTICE! A reset process is only possible in the event of a system error. PLEASE ROCEED AS FOLLOWS Reset 1 (actuators):...
Page 71
❖ The reset process is complete when the described positions are reached. This process must be carried out manually, i.e. each drive must be run individually. Please note that you keep the buttons pressed for 2-3 seconds longer after reaching the end position. WARNING! The adjustment (initialization) must be carried out manually, i.e.
16. Cleaning and maintenance of the MLR S ELECT WARNING Always disconnect the MLR S from the mains ELECT (unplug) before cleaning and maintenance. RISK OF ELECTRIC SHOCK! RISK OF FIRE! WARNING! Regularly remove any dust build-up from the mains plug, the safety socket, and all electrical plug connections, e.g.
16.1.2 Cleaning and care of the artificial leather ❖ Clean the artificial leather only with a soft cloth with a small amount of a detergent suitable for this material (also available from Gharieni: see chapter UPHOLSTERY CARE AND CLEANING AGENTS...
16.3 Cover of the upholstery ❖ The upholstery of the MLR S is equipped with a surface made of ELECT polyurethane (PU). To protect these material (polyurethane) as well as the actual upholstery, we recommend the use of suitable PROTECTIVE COVERS ROTECTIVE COVERS AVAILABLE AT HARIENI ROUP...
17. Malfunctions (possible causes and troubleshooting) ALFUNCTION OSSIBLE CAUSE ROUBLESHOOTING LL MOTORS DO NOT WORK 1. No connection to the mains. 1. Check the connection status. 2. The power supply cable is damaged. 2. Power supply cable must be replaced (please contact the customer service).
7. Check the power cord regularly for signs of damage. 8. If the mains cable is damaged, it may only be replaced by Gharieni Group GmbH, or a customer service authorized by Gharieni Group GmbH or a qualified specialist (electrical engineer).
18. Optionally available accessories For detailed information regarding the optionally available accessories (s. below) please contact our sales department. Our team is happy to help! 18.1 Headrests 18.1.1 Dual headrest This newly designed headrest offers full flexibility for every requirement. This headrest has a round or a horn-shaped face cushion.
18.2 Gel cushions for nose slots ❖ G for the headrest of the MLR S are optional available for an EL CUSHIONS ELECT additional charge. ❖ The are available in different variants. GEL CUSHIONS ❖ The are perfectly suited for prone positions (massage positions). GEL CUSHIONS ❖...
For detailed information regarding the right size and suitable version for the headrest of your Spa Table please contact our sales department. Our team is happy to help! 18.4 Neckrest “Dentalax” ❖ For the MLR S , our popular “D ”...
18.5 Protective covers 18.5.1 Protective covers made of terry ❖ P for our Spa Tables are optional available ROTECTIVE COVERS MADE OF TERRY for an additional charge (s. fig. below). ❖ The are available as a 5-piece set; PROTECTIVE COVERS MADE OF TERRY with or without oil-repellent coating made of polyurethane (PU).
18.5.2 Protective covers made of polyurethane (PU) ❖ P (PU) for our Spa Tables (s. fig. ROTECTIVE COVERS MADE OF POLYURETHANE below) are optional available for an additional charge. ❖ A P PU serves as a second outer skin for the Spa ROTECTIVE COVER MADE OF Table, so to speak.
: 49052 ROTECTIVE FOOT COVER RTICLE NUMBER NOTICE! We recommend ordering the protective foot cover directly when purchasing your Spa Table. In this case the fleece strip (Counter- Velcro / part of the hook and loop fastener) is already fixed on the Spa Table at delivery so that you can fasten the protective foot cover easily and comfortably.
NOTICE! Please see our separate assembly and instruction manual. 18.8 Aroma therapy / fragrance generator NOTICE! Operation of the fragrance generator is only possible with the optional hand control with memory function. Wellness with all senses: Enchant your customers with soothing fragrances. With the integrated fragrance generator, your treatment becomes a scentful experience.
Page 84
Matching the fragrance generator: PERFUME PEARLS STARTER : 36008 ITEM NUMBER TYPES Á ML IN A PLASTIC BAG The fragrances are also available individually, in the 150 g tin. NOTICE! During adjustment of the bed, the fragrance generator is switched off for a short time. After the bed has been adjusted, it is switched on again.
19. Upholstery care and cleaning agents ® 19.1 mikrozid sensitive (alcohol-free) ® ❖ We recommend mikrozid sensitive for gentle and thorough disinfection, care, and cleaning of the upholstery. ® ❖ mikrozid sensitive removes bacteria, fungi, and viruses (e.g. HBV, Rota, Vaccinia etc.).
Page 86
For more information, visit the manufacturer’s website at the following link: https://www.schuelke.com/intl-en/products/mikrozid-sensitive-liquid.php...
19.2 Skai cleaner ❖ For gentle and thorough care and cleaning of the artificial leather upholstery we additionally recommend Skai cleaner. ❖ Skai cleaner is available in a 200 ml spray bottle. ❖ Especially suitable for cleaning artificial leather. : 79427 KAI CLEANER TEM NUMBER...
20. Conditions of transport, storage, and operation 20.1 Transport ❖ During transport, lift the MLR S using the carrying aids only ELECT (s. chapter 6.2.1 U SE OF THE CARRYING AIDS ❖ Never carry the MLR S by its lying / sitting surface or its armrests during ELECT transport;...
21. Technical Data MLR S ELECT ENERAL TECHNICAL DATA Total length 200 cm Total width Small 76 cm Total width MediumSmall 80 cm Total width Medium 85 cm Total width Large 92 cm Weight approx. 120 kg - 150 kg (depending on the design of the base) Adjustable height MLR S...
Page 90
DRIVES INCL CONTROLS Power supply 100 - 240 V ~ , 50 - 60 Hz Power consumption Output: approx. 350 W Standby power: approx. 0,5 W Output voltage 24 V DC Duty cycle (actuator) 10 % max. 2 min. continuous operation / 18 min.
9. If suitable containers are not available at your residential area, dispose of these materials at a suitable municipal collection point for waste-recycling. 10. Receive more detailed information from your retailer, municipal facilities or: Gharieni Group GmbH ➢ Phone: +49 (0)2841/88300-0 ➢...
23. Warranty The following warranty conditions apply to new goods worldwide: Gharieni Group GmbH grants on all spa tables of the MLR S series: ELECT → 10 years warranty on metal frames → 5 years warranty on actuators and → 3 years warranty on other components.
24. EC-Declaration of Conformity EC-Declaration of Conformity Gharieni Group GmbH Gutenbergstraße 40 47443 Moers / Germany hereby declare, in sole responsibility, that, due to its design and construction, the device named below complies with the relevant, fundamental safety and health requirements of the EU.
THE OWNERSHIP RIGHTS TO THIS INSTRUCTION MANUAL ARE RESERVED. REPRODUCTION OR TRANSFER TO THIRD PARTIES IS PROHIBITED WITHOUT THE CONSENT OF GHARIENI GROUP GMBH. GHARIENI GROUP GMBH RESERVES THE RIGHT TO PROTECT ITS PROPERTY RIGHTS AND TO PROSECUTE ANY MISUSE. RODUCTION...
Need help?
Do you have a question about the MLR SELECT V2 and is the answer not in the manual?
Questions and answers