Lp Conversion Instructions - Regency City CV60E-1 Owners & Installation Manual

Direct vent
Hide thumbs Also See for City CV60E-1:
Table of Contents

Advertisement

installation

LP Conversion Instructions

LP Conversion Instructions
WARNING
WARNING
This conversion kit shall be installed by a qualified ser-
This conversion kit shall be installed by a qualified ser
vice agency in accordance with the manufacturer's in-
vice agency in accordance with the manufacturer's in
structions and all applicable codes and requirements
structions and all applicable codes and requirements
of the authority having jurisdiction. If these instructions
of the authority having jurisdiction. If these instructions
is not followed exactly, a fire, explosion or production
is not followed exactly, a fire, explosion or production
of carbon monoxide may result causing property dam-
of carbon monoxide may result causing property dam
age, personal injury or loss of life. The qualified service
age, personal injury or loss of life.The qualified service
agency is responsible for the proper installation of this
agency is responsible for the proper installation of this
kit. The installation is not proper and complete until
kit. The installation is not proper and complete until
the operation of the converted appliance is checked as
the operation of the converted appliance is checked as
specified in the manufacturer's instructions supplied
specified in the manufacturer's instructions supplied
with the kit.
with the kit.
Conversion Kit 686-969 includes:
Conversion Kit 686-969 includes:
1
911-191
Stepper Motor LP for 885 SIT
1
911-191
Stepper Motor LP for 885 SIT
1
905-046
Orifice #50
1
905-046
Orifice #50
1
910-037
Pilot Orifice #30
1
910-037
Pilot Orifice #30
1
918-590
Decal - Conversion to LP
1
918-590
Decal - Conversion to LP
1
908-528
Label Propane
1
908-528
Label Propane
1
904-529
5/32" long Allen Key
1
904-529
5/32" long Allen Key
1
920-179
Instruction Sheet
1
920-225
Instruction Sheet
Caution:The gas supply shall be shut o prior to disconnecting the
electrical power, before proceeding with the conversion.
Caution: The gas supply shall be shut off prior to disconnecting the
electrical power, before proceeding with the conversion.
Always let the appliance cool to room temperature before servicing.
Always let the appliance cool to room temperature before servicing.
1 Remove the outer panels and safety glass — see manual.
1 Remove the outer panels and safety glass — see manual.
2.
Remove
inner
glass — see manual.
2. Remove inner firebox glass — see manual.
3. Remove inner panels — see manual.
3. Remove inner panels — see manual.
4.
Remove
all media installed on burner (glass, logs or stones, etc).
4. Remove all media installed on burner (glass, logs or stones, etc).
5. Lift o the far right base panel and loosen 2 screws on IFC cover--re
moved cover to access IFC.
5. Lift off the far right base panel and loosen 2 screws on IFC cover--re-
moved cover to access IFC.
920-179
920-225
74 ............................................. |City Series CV60E-1
74 | City Series CV60E-1
CONVERSION FROM NG TO LP
CONVERSION FROM NG TO LP
CV60E using SIT 885 NOVA Gas Valve
CB60E using SIT 885 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!
IF IN DOUBT DO NOT DO THIS CONVERSION!
tooltip
Base Panel
IFC cover
CV60E shown
6. Disconnect the Cable coming from the Pressure Regulator Motor.
6. Disconnect the Cable coming from the Pressure Regulator Motor.
-
-
Cable from motor
-
7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slot
7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slot
screwdriver,) Pressure Regulator (B) and Spring and Diaphragm (C)
screwdriver,) Pressure Regulator (B) and Spring and Diaphragm (C)
(see below).
(see below).
8. Ensure the rubber gasket, which is prefitted as part of the Assembly,
8. Ensure the rubber gasket, which is prefitted as part of the Assembly,
is properly positioned. Install the new Pressure Regulator using the 2x
is properly positioned. Install the new Pressure Regulator using the 2x
M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that
M4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event that
the screw threads are cross threaded or stripped, replace the valve as
the screw threads are cross threaded or stripped, replace the valve as-
sembly.
sembly.
Install the enclosed propane identification label to the valve body where it
Install the enclosed propane identification label to the valve body where it
can be easily seen.
can be easily seen.
Pressure
regulator
Pressure
screws
regulator
screws
9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re-
tooltip
-
situate the IFC, secure the screws that fasten the IFC Mounting Brackets.
9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re-
10. Remove pilot hood by lifting up and o .
situate the IFC, secure the screws that fasten the IFC Mounting Brackets.
Pilot hood
10. Remove pilot hood by lifting up and off.
Pilot hood
11. Remove the trim cover on right side of burner by lifting o . Also remove
the burner surround by sliding to the left and lifting o .
11. Remove the trim cover on right side of burner by lifting off. Also remove
the burner surround by sliding to the left and lifting off.
Trim cover
Trim cover
1
1
CITY SERIES 60
CITY SERIES 60
installation
Cable from motor
Burner Surround
Burner Surround
City Series CBV0E
-
10.31.19
| 59
06.09.20

Advertisement

Table of Contents
loading

This manual is also suitable for:

City cv60e-ng1City cv60e-lp1

Table of Contents