Lamp Runtime Warning: Do not exceed the indicated maximum total lifetime of the lamp for safe operation in normal power mode. Do not use it longer ! Always replace the lamp with the BARCO lamp kit for IQ projectors. R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Page 8
1. Safety R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Depending on the Kitnumber ordered the kit may contain 1 or 2 lamps, the lamp power may also differ according to the type of iQ Projector. Kitnumber Description Quantity Manual IQ200 R9841771 120 W Lamp R5976375 R9841770 120 W Lamp R5976375 IQ300 R9841111 200 W Lamp R5976375 R9841100 200 W Lamp R5976375...
Page 10
2. Kit Content R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
8. Use ←or →, the numeric keys on the remote, or the keypad to change the serial number of the lamp (serial number 0000000 will not be accepted). Image 3-1 Image 3-2 Lamp runtime reset as well as the lamp replacement can only be done by a Barco authorized technician. R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Page 12
3. Reset runtime R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
4. Access to the lamp unit(s) 4. ACCESS TO THE LAMP UNIT(S) 4.1 Removing the back cover Necessary tools a flat screwdriver of 10 mm Necessary parts No parts. Risk of Electrical Shock: For replacement procedures power down the projector and unplug the power cord from the wall outlet.
Page 14
4. Access to the lamp unit(s) R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Page 15
5. Removing the lamp unit(s) 5. REMOVING THE LAMP UNIT(S) 5.1 Removing the lamp unit(s) What has to be done ? The lamp power connection has to be disconnected. The lamp unit has to be removed. Perform the procedure for both lamps if necessary. In this procedure lamp1 is replaced, the procedure being the same for lamp2.
Page 16
5. Removing the lamp unit(s) Image 5-4 Image 5-3 unlocking lamp 1 & lamp 2 Image 5-5 Lamp 1 removed R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Page 17
6. Mounting the Lamp Unit 6. MOUNTING THE LAMP UNIT 6.1 Mounting the lamp unit(s) What has to be done ? The lamp has to be mounted The lamp has to be connected. Perform the procedure for both lamps if both lamps have to be replaced. In this procedure lamp1 is replaced, the procedure being the same for lamp2.
Page 18
6. Mounting the Lamp Unit R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
7. Mounting the cover. 7. MOUNTING THE COVER. 7.1 Mounting the cover. Mounting the back cover 1. Replace the back cover. 2. Turn with a screwdriver the cover lock screw a quarter turn clockwise to lock the cover. (image 7-1) Image 7-1 R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Page 20
7. Mounting the cover. R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...
Page 21
Index INDEX mounting removing access runtime reset Content Menu cover 7, 13 Lamp menu mounting reset runtime removing Runtime reset content safety lamp 5, 7, 9, 11 guidelines access R5976375 LAMP KIT FOR IQ PROJECTORS 05112002...