Easy and Reliable
The Fiber Sensor
New Model with Four-color Determination for Even
More Complete Color-sensing Fiber Sensors
That
Sees
in
Color
C
S
olor
ensing

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E3X-DAC-S Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Omron E3X-DAC-S Series

  • Page 1 Color Sensing Digital Fiber Sensor E3X-DAC-S Easy and Reliable The Fiber Sensor That Sees Color New Model with Four-color Determination for Even More Complete Color-sensing Fiber Sensors olor ensing...
  • Page 2 C o l o r - S e n s i n g E n g i n e olor ensing Easy and Reliable ... Featuring a Color-sensing Engine The color-sensing engine uses three parameters, RGB, to process Precise incident light. It detects color information from the workpiece for precise Detection detection of color differences.
  • Page 3 A double display for easy, precise setting. Easy and Reliable ... Simplified Wiring Connector Reduces Work Steps OMRON's unique simplified wiring connectors provide the power for each added Sensor. Up to 16 Units can be mounted, including a combination of Digital Fiber Sensors and other simplified wiring connector products such as Digital Laser Sensors.
  • Page 4 A p p l i c a t i o n Many Compact Heads Long-distance Fiber Head Wide Range of E32-A09 General-purpose 23 mm Fiber Heads Available Fiber Head E32-CC200 9 mm Select from a wide range of Fiber Heads to match 20 mm the workpiece and working space.
  • Page 5: Ordering Information

    E3X-DAC-S Ordering Information Amplifier Units Pre-wired model (Standard cable length 2 m) Model Item Appearance Functions NPN output PNP output Standard models Timer, Response speed change E3X-DAC11-S 2M E3X-DAC41-S 2M Advanced models Standard models + Simultaneous deter- (2-color simultaneous mination (2 colors), AND/OR output, Re- E3X-DAC21-S 2M E3X-DAC51-S 2M determination)
  • Page 6 E3X-DAC-S Ratings and Specifications Amplifier Units Advanced models Advanced models Type Standard models (2-color simultaneous (4-color determination) determination) Item Model E3X-DAC@-S@ (@: 11/41/6/8) E3X-DAC@-S@ (@: 21/51) E3X-DAC@B-S@ (@: 21/51) Sensing distance Depends on the Fiber Unit. Refer to pages 8 to 10. Reflective models: Standard 11 color cards (See note 1.), Through-beam models: Opaque or translucent ob- Sensing object ject...
  • Page 7 E3X-DAC-S Advanced models Advanced models Type Standard models (2-color simultaneous (4-color determination) determination) Item Model E3X-DAC@-S@ (@: 11/41/6/8) E3X-DAC@-S@ (@: 21/51) E3X-DAC@B-S@ (@: 21/51) Weight (packed state) Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g Case Polybutylene terephthalate (PBT) Materials Cover...
  • Page 8 E3X-DAC-S Sensing Distance Threaded Models Through-beam Fiber Units Sensing distance (mm) Opaque object (Translucent object) * Sensing direction Size Model High- High- Standard High-speed Super-high- Standard High-speed Super-high- resolution resolution mode mode speedmode mode mode speedmode mode mode Right-angle E32-T11N 2M Straight E32-T11R 2M * These sensing distances are recommended to make the most of the detection capabilities of the Sensor.
  • Page 9 E3X-DAC-S Sleeve Models Through-beam Fiber Units Sensing distance (mm) Opaque object (Translucent object) * Sensing direction Model High- High- Standard High-speed Super-high- Standard High-speed Super-high- resolution resolution mode mode speedmode mode mode speedmode mode mode Top-view E32-TC200BR 2M * These sensing distances are recommended to make the most of the detection capabilities of the Sensor. Reflective Fiber Units Sensing distance (mm) Standard color card (11 colors)
  • Page 10 E3X-DAC-S Chemical-resistant, Oil-resistant Through-beam Fiber Units Sensing distance (mm) Opaque object (Translucent object) * Sensing Type Model High- High- direction Standard High-speed Super-high- Standard High-speed Super-high- resolution resolution mode mode speedmode mode mode speedmode mode mode E32-T12F 2M Chemical/oil-re- Top-view E32-T11F 2M sistant Side-view...
  • Page 11 E3X-DAC-S Area Beam Through-beam Fiber Units Sensing distance (mm) Opaque object (Translucent object) * Type Sensing width Model High- High- Standard High-speed Super-high- Standard High-speed Super-high- resolution resolution mode mode speedmode mode mode speedmode mode mode E32-T16PR 2M 11 mm Area E32-T16JR 2M 30 mm...
  • Page 12 E3X-DAC-S Engineering Data (Reference Value) Color vs. Detection Capability E3X-DAC@-S+E32-CC200 Yellow/ Yellow/ Blue/ Blue/ Red/ ∗ White Yellow Green Blue Purple Black green green purple purple Model with Red Light Source ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍...
  • Page 13 E3X-DAC-S Output Circuit Diagrams NPN Output Operation Operation Model Timing charts Output circuit mode selector Match Mismatch Operation Operation I mode indicator (orange) Display ON for indicator LIGHT ON indicator Brown (orange) (Orange) Output match (L-ON) transistor Load Black Load Operate (relay) Photo-...
  • Page 14: Safety Precautions

    E3X-DAC-S Nomenclature Amplifier Units Standard Models Advanced Models (2-color simultaneous determination, E3X-DAC@-S (@: 11/41/6/8) 4-color determination) E3X-DAC@-S (@: 21/51), E3X-DAC@B-S (@: 21/51) Main Display (Red) Sub-Display (Green) Operation Keys Sub-Display (Green) Main Display (Red) Operation Keys Function setting operations Incident level, function, etc. Threshold, function settings, etc.
  • Page 15 E3X-DAC-S Precautions for Correct Use Do not use the product in atmospheres or environments that Adding and Removing Amplifier Units exceed product ratings. Adding Amplifier Units Amplifier Unit 1. Mount the Amplifier Units one at a time onto the DIN track. ●...
  • Page 16 E3X-DAC-S 2. Disconnecting Fibers Fiber Unit ● Design Precautions Remove the protective cover and raise the lock lever to pull out the fibers. Applicable Fiber Units Refer to the sensing distance tables on pages 8 to 11 for the Fiber Units that can be used and the sensing distances. Ret- ro-reflective, Limited-reflective, Ultra-compact, and Applica- Protective cover tion-specific Fiber Units, which are not listed, cannot be used.
  • Page 17 E3X-DAC-S Dimensions (Unit: mm Amplifier Units Amplifier Units with Cables Round ( ): I Mode indicator Operation indicator Oblong ( ): Operation indicator for channel 2 E3X-DAC11-S E3X-DAC41-S E3X-DAC21-S E3X-DAC51-S Vinyl-insulated round cable Main display Sub-display E3X-DAC21B-S Standard length: 2 m * E3X-DAC51B-S * Cable Specifications 4-dia., 3-conductor (Conductor...
  • Page 18 E3X-DAC-S Amplifier Units with Connectors Round ( ): I Mode indicator Operation indicator Oblong ( ): Operation indicator E3X-DAC6-S E3X-DAC8-S Sub-display Main display With Mounting Bracket Attached *1 The Mounting Bracket can also be 3.9 × 3 = 11.7 32.8 used on this side.
  • Page 19 E3X-DAC-S Operation Operation Reference Main Display (Red) Sub-Display (Green) Operation Keys Threshold, Function setting operations Match, function, etc. function settings, etc. DOWN MODE Standard models: I Mode indicator Operation Indicator Advanced models: Operation for Channel 1 indicator for channel 2 Mode Selector Use to select SET or RUN mode.
  • Page 20 E3X-DAC-S Changing Banks (for Advanced Models (4-color Determination)) The bank where data is registered can be changed by using the bank input and the channel switch. Bank Bank input Open Open Closed Closed Channel switch Display Setting the Operation Mode 3-2.
  • Page 21 E3X-DAC-S Setting Functions in SET Mode *. The displays shown in the function transitions are for the default settings. *. Items shown in the function transitions may increase depending on detailed settings. *. The items enclosed by dotted red lines are for advanced models only. Function Transitions ➜...
  • Page 22 E3X-DAC-S Convenient Functions 6-1. Zeroing the Display (Zero Reset) 6-3. Saving a Set State (Saving User Settings) The incident light level on the main display can be set to ∗ Set the SET/RUN Mode MODE Press 0. This is useful when the reference display is to be reset Selector to SET.
  • Page 24 Buyer indemnifies Omron against all related costs or expenses. rights of another party. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-...