INSTALLATION INSTRUCTIONS
5.
Prepare RO system for installation - continued
Fig. 5
Disconnect the 1/4" tube connection going into
the membrane cap by unscrewing the plastic nut
counter-clockwise.
Remove the blue membrane (#4) from its
packaging.
Insert the membrane end with the two O-rings
into the housing until it clicks in place.
Do not force the membrane to seat.
Re-install the membrane housing cap by screwing
it clockwise until firmly in place, being careful to
not overtighten. Re-install the 1/4" tube connection
by screwing the plastic nut clockwise until tight.
8
INSTALLATION MANUAL
AquaWave
Classic Reverse Osmosis System
6.
Install RO faucet
Fig. 6
Remove the faucet base from the package and
ensure it can mount flat against the surface before
drilling an 7/8" (22mm) hole to house the faucet.
NOTE: Drilling holes into solid surfaces or surfaces
made of stone should only be performed by a
qualified installer.
Assemble the faucet by inserting the spigot into
the top threaded hole of the handle section and
tighten the nut to lock it in place.
NOTE: Make sure all tubing cuts are done squarely
and evenly to ensure proper sealing.