Technical Data And Components - Global Water AquaWave Classic 75GPD Installation, Operation & Maintenance Manual

Reverse osmosis (ro) system
Table of Contents

Advertisement

BEFORE CHANGING THE FILTERS OF YOUR RO SYSTEM
Unplug the electricity plug of the pump and make sure no electricity is flowing into the system.
Turn off the 1/4" water supply valve.
Close the RO tank ball valve..
Turn the RO faucet on so the water runs out of the system. Wait until there is no more water running.
Water may spill during the filter changing process. Therefore we suggest performing the filter changes over a towel
or bucket to catch the spilling water.
A NOTE TO THE HOMEOWNER
Stage 1 - PP1005
Use the wrench to unscrew the Stage 1 housing.
Remove the PP filter from inside the housing and dispose of it. Wash and rinse out the housing with regular water.
Place the new PP filter into the housing and screw the housing back to its cap. Hand tighten until snug then use
wrench to turn one additional 1/4 turn. Do not overtighten.
Stage 2 - M01-GT-BW
Same as Stage 1
Stage 3 - M11-GT-WN
Same as Stage 1 and 2
Stage 4 - R2W75GPD-Replacement RO Membrane
Open the RO membrane housing by unscrewing the membrane housing and remove the RO membrane using pincers.
Dispose of the RO membrane.
Unpack the new replacement RO membrane from its packaging and insert the membrane end with the two O-rings
into the housing until it clicks into place. Do not force the membrane to seat.
Replace the RO membrane housing cap and hand tighten.
Stage 5 - K02-GT-WW-TP
Remove the used GAC post-filter from the RO unit by unscrewing the T-piece on one side and the L-piece on the
other side and taking it out of its holding clips. Dispose of the GAC post filter.
Put your new GAC post-filter into the holding clips. Make sure to check the arrow on the GAC post-filter and install it in
the correct direction (same direction as old GAC post-filter).
Screw the L-piece connection to the exit side (tip of the arrow) of the GAC post-filter using Teflon tape (same direction
as old GAC post-filter).
Screw the T-piece connection into the GAC post-filter (same direction as old GAC post-filter).
14