Installation Instructions - Global Water AquaWave Classic 75GPD Installation, Operation & Maintenance Manual

Reverse osmosis (ro) system
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

If inlet water pressure is over 50 psi, a pressure
regulator must be installed and set at 40 psi or less.
You must check and comply with all local plumbing
codes.
1.
Install water supply valve.
Fig. 1
Identify the cold water supply line under the sink
cabinet. Shut the cold-water supply valve.
Turn on the cold-water tap to release pressure
from the lines until water flow stops.
Disconnect the cold-water line from the angle stop
valve and identify if it is a 1/2" or 3/8" connection
and select appropriate water supply adaptor.
Assemble the 1/4" water supply valve into the
appropriate diameter water supply adaptor using
Teflon™ tape on male threads before insertion.
Wrap threads of water supply adaptor and angle
stop valve 2-3 times with Teflon™ tape.
Screw the water supply adaptor to angle stop
valve and tighten with adjustable wrench.
Screw the cold-water supply line to threads of
water supply adaptor and tighten with adjustable
wrench.
5 Stage Reverse Osmosis System
2.
Install waste water clip
Fig. 2
Identify the drain outlet location. Make sure that it
is away from the garbage disposal See Fig.2.
Knock out center hole on foam seal.
Use the hole in foam seal as a template to locate
your drilling position above the drain trap, mark
exact location with a pencil.
At the marked location, drill 1/4" (6.35mm) hole
through the wall of the drain-pipe. Be sure not to
penetrate opposite side of the pipe.
Remove protective cover from the back of foam
seal and attach it to the front plate drain connector
in alignment with drain tube hole.
Begin to position the drain connector on sink
drain- pipe with screws and nuts, using your
pencil in the drain connector tube hole to guide
your location over your drilled hole as you securely
tighten nuts and screws.
5