INSTALLATION INSTRUCTIONS
9.
Install RO storage tank
Fig. 9
Wrap stainless steel thread connection on top of
storage tank with Teflon™ tape.
Hand-tighten the tank ball valve to the stainless
steel connection as shown in Fig. 9.
Place tank in vertical position in the cabinet.
Measure length of 1/4" white tubing from outlet of
ball valve to the inlet of the post-carbon polishing
filter as shown in Fig. 9.1.
Cut tube accordingly and insert one end of tube
into 1/4" compression fitting of ball valve, gently
tugging to ensure it is in place.
Fig. 9.1
10
INSTALLATION MANUAL
AquaWave
Classic Reverse Osmosis System
10.
Connect tubing to RO system
Fig. 10
Connect 1/4" white tube from outlet of flow
restrictor to drain connection on waste water clip.
Connect 1/4" white tube from bottom of faucet
threaded stem to outlet of post-carbon polishing
filter by unscrewing the plastic nut, inserting the
tube and screwing back finger-tight.
Connect 1/4" white tube from main water supply
to inlet of 1st stage (marked "IN").
Connect 1/4" white tube from tank ball valve to
inlet of post-carbon polishing filter.