4.0 Operation 1.1 Your New Giorik Product ....3 4.1 Gas Operation - Chrome Plated ....24 1.2 Australia and New Zealand Warranty .
Page 4
Thank you for choosing this quality Giorik product. All Giorik products are designed and manufactured to meet the needs of food service professionals. By caring for and maintaining this new Giorik product in accordance with these instructions, will provide many years of reliable service.
700/900 1.0 Introduction Warranty & Registration 1.2 Australia and New Zealand Warranty 1.2.1 Warranty Period All Stoddart manufactured and distributed products are covered by Stoddart’s standard Australia and New Zealand Product Warranty (minimum 12 month on-site parts and labour, terms and conditions apply). Further to this standard warranty, certain products have access to an extended warranty.
1.0 Introduction 1.3 General Precautions When using any electrical unit, safety precautions must always be observed. • All units MUST be installed according to the procedures stated in the installation section of this manual • In the case of new personnel, training is to be provided before operating the equipment •...
Page 7
700/900 1.0 Introduction 1.4 Setting Up Information IMPORTANT To be installed only by an authorised service person WARNING Improper installation, adjustments, alterations, service or maintenance can cause property damage, injury or death 1.4.1 Handling • Use suitable means to move the unit; - For smaller items use two people - For large items a fork lift, pallet trolley or similar (the forks should reach completely beneath the pallet) 1.4.2 Unpacking...
2.65 kPa Total Nominated Gas Consumption 25 MJ/h 25 MJ/h Legend Gas Connection 2.2.2 Gas - 700 Series - 400mm Open Base 700 Series - Gas Satin Chrome - Smooth Plate FLG72GCRXT Satin Chrome - Ribbed Plate FRG72GCRXT Mild Steel - Smooth Plate...
Page 11
2.65 kPa Total Nominated Gas Consumption 50 MJ/h 50 MJ/h Legend Gas Connection 2.2.4 Gas - 700 Series - 800mm Open Base 700 Series - Gas Satin Chrome - Smooth Plate FLG741GCRXT Satin Chrome - Ribbed Plate FRG741GCRXT Satin Chrome - Ribbed / Smooth Plate...
Page 12
2.0 Specification 2.2.5 Gas - 900 Series - 400mm Countertop 900 Series - Gas Satin Chrome - Smooth Plate FLG92TCRXT Satin Chrome - Ribbed Plate FRG92TCRXT Mild Steel - Smooth Plate FLG92TFT Mild Steel - Ribbed Plate FRG92TFT W x D x H (mm) 400 x 920 x 367 Weight 70kg...
Page 14
Electrical Connection 3Ø + N + E 415VAC / 50Hz / 6.5kW Legend Electrical Connection 2.2.10 Electric - 700 Series - 400mm Open Base 700 Series - Electric Satin Chrome - Smooth Plate FLE72GCRXT Satin Chrome - Ribbed Plate FRE72GCRXT...
Page 15
Electrical Connection 3Ø + N + E 415VAC / 50Hz / 13kW Legend Electrical Connection 2.2.12 Electric - 700 Series - 800mm Open Base 700 Series - Electric Satin Chrome - Smooth Plate FLE741GCRXT Satin Chrome - Ribbed Plate FRE741GCRXT...
Page 16
2.0 Specification 2.2.13 Electric - 900 Series - 400mm Countertop 900 Series - Electric Satin Chrome - Smooth Plate FLE92TCRXT Satin Chrome - Ribbed Plate FRE92TCRXT Mild Steel - Smooth Plate FLE92TFT Mild Steel - Ribbed Plate FRE92TFT W x D x H (mm) 400 x 920 x 367 Weight 70kg...
3.0 Installation 3.1 Positioning WARNING Improper installation, adjustments, alterations, service or maintenance can cause property damage, injury or death. 3.1.1 General Information • The unit must be installed under an extraction canopy • Have a smooth, level floor which can bear the weight of the unit at full load •...
Page 19
700/900 3.0 Installation 3.2 Line-up Connection WARNING Must be installed only by an authorised service person If the unit is already installed and connected to power, the power to the equipment must be turned off and isolated. FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK. •...
Page 20
3.0 Installation • Place the units to be connected next to each other, adjust the legs ensuring the top of the two units sit flush • Using the provided bolts and nuts connect the units at the front and rear •...
700/900 3.0 Installation 3.3 Gas Connection WARNING This unit must be installed by an authorised person/installer in accordance with this instruction manual, AS/NZS 5601 – Gas installations (installation and pipe sizing), local gas fitting regulations, local electrical regulations, local water regulations, local health regulations, Building Code of Australia and any other government authority.
3.0 Installation 3.3.3 Gas Pressure Check Seal Screw Ensure Burner Gas pressure matches the rating label (see page 8 / 2.1.6 Fig 1.). Pressure outlet If the gas operating pressure is incorrect, adjust pressure regulator installed on the Test Point incoming gas supply to the unit.
700/900 3.0 Installation 3.4 Gas Conversion IMPORTANT Gas Conversion must only be carried out by an authorised person. Incorrect installation may void warranty If the unit is to be connected to a different type of gas than that for which it has been prepared, the nozzles must be replaced. Please contact Stoddart for the approved Gas conversion Kit and settings.
3.0 Installation 3.5 Electrical Connection 3.5.1 Information WARNING This unit must be installed in accordance with AS/NZS 60335.1 Some procedures in this manual require the power to the equipment to be turned off and isolated. Turn the power OFF at the power point and unplug the power supply lead by the plug body.
700/900 4.0 Operation 4.1 Gas Operation - Chrome Plated WARNING Hot surfaces! DO NOT TOUCH Contact with skin may cause burns WARNING DO NOT spray aerosols in the vicinity of the appliance when operating. 4.1.1 Controller Configuration Control Panel - Thermostatic Symbol Description Pilot Flame...
Page 26
4.0 Operation 4.2 Gas Operation - Mild Steel WARNING Hot surfaces! DO NOT TOUCH Contact with skin may cause burns WARNING DO NOT spray aerosols in the vicinity of the appliance when operating. 4.2.1 Controller Configuration Control Panel - Hi-Lo Symbol Description Pilot Flame...
700/900 4.0 Operation 4.3 Electric Operation WARNING Hot surfaces! DO NOT TOUCH Contact with skin may cause burns 4.3.1 Controller Configuration Control Panel - Thermostatic Symbol Description °C Temperature Range 80°C - 290°C (MAX) Green Indicator Light (Heating) Red Indicator Light (Power) Fig.12.
5.0 Cleaning and Maintenance 5.1 Cleaning 5.1.1 Cleaning Schedule • Daily cleaning is required for the appliance, to help maintain and prolong the appliance efficiency • The appliance should be cleaned at the end of each service period • DO NOT USE: Wire brushes, steel wool/sponges, scrapers or other abrasive materials •...
Page 29
700/900 5.0 Cleaning and Maintenance 5.1.6 Cleaning Procedure (Daily) Isolate unit from the power supply Using a scraper remove crumbs and small food items from the steel plate Remove the drip tray. Empty the drip tray and clean with warm soapy water. Thoroughly dry Remove the grill rack and crumb tray.
5.0 Cleaning and Maintenance 5.2 Maintenance WARNING Maintenance tasks are only to be completed by authorised service people 5.2.1 Periodic Maintenance All controls and mechanical parts of the appliance should be checked and adjusted periodically by a qualified service person. Contact the Stoddart service department to arrange a service Maintenance / Inspections Possible Causes...
Page 31
700/900 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 30...
Page 32
Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au Service Request www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz Email: sales@stoddart.co.nz Email: spares@stoddart.co.nz...