Giorik GL720TGCT Installation, Operation & Maintenance Manual

Char grill

Advertisement

Quick Links

INSTALLATION / OPERATION / MAINTENANCE
MANUAL
(READ ALL INSTRUCTIONS BEFORE USE)
700/900
CHAR GRILL
Models:
700 Series:
GL720TGCT / GL720GCT
GL740TGCT / GL740GCT
Revision: A - 19/12/2022 - 01
900 Series:
GL920TGCT / GL920GCT
GL940TGCT / GL940GCT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GL720TGCT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Giorik GL720TGCT

  • Page 1 INSTALLATION / OPERATION / MAINTENANCE MANUAL (READ ALL INSTRUCTIONS BEFORE USE) 700/900 CHAR GRILL Models: 700 Series: 900 Series: GL720TGCT / GL720GCT GL920TGCT / GL920GCT GL740TGCT / GL740GCT GL940TGCT / GL940GCT Revision: A - 19/12/2022 - 01...
  • Page 2 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 1...
  • Page 3 4.0 Operation 1.1 Your New Giorik Product ....3 4.1 Lava Stones ..... . . 19 4.1.1 Lava Stone Placement...
  • Page 4 Thank you for choosing this quality Giorik product. All Giorik products are designed and manufactured to meet the needs of food service professionals. By caring for and maintaining this new Giorik product in accordance with these instructions, will provide many years of reliable service.
  • Page 5: Warranty And Registration

    700/900 1.0 Introduction Warranty & Registration 1.2 Australia and New Zealand Warranty 1.2.1 Warranty Period All Stoddart manufactured and distributed products are covered by Stoddart’s standard Australia and New Zealand Product Warranty (minimum 12 month on-site parts and labour, terms and conditions apply). Further to this standard warranty, certain products have access to an extended warranty.
  • Page 6: General Precautions

    1.0 Introduction 1.3 General Precautions When using any electrical unit, safety precautions must always be observed. • All units MUST be installed according to the procedures stated in the installation section of this manual • In the case of new personnel, training is to be provided before operating the equipment •...
  • Page 7 700/900 1.0 Introduction 1.4 Setting Up Information IMPORTANT To be installed only by an authorised service person WARNING Improper installation, adjustments, alterations, service or maintenance can cause property damage, injury or death 1.4.1 Handling • Use suitable means to move the unit; - For smaller items use two people - For large items a fork lift, pallet trolley or similar (the forks should reach completely beneath the pallet) 1.4.2 Unpacking...
  • Page 8: Specification

    2.1.3 Burner Configuration Main Injector Bypass Screw (mm) Total Nominal Gas Fixed Aeration (100th of mm) Consumption (MJ/h) Shutter Setting ‘A’ Natural Gas GL720TGCT / GL720GCT 36 MJ/h 13mm GL740TGCT / GL740GCT 72 MJ/h 13mm GL920TGCT / GL920GCT 54 MJ/h 13mm...
  • Page 9 The rating plate contains identification and technical data. See example below. Confirm that this unit has been tested and approved for the type of gas used at the installation location. Imported by: STODDART www.stoddart.com.au Description: Giorik; 700 Char Grill; Gas; 400mm; On Base Main burner gas injector GL720GCT Model No:...
  • Page 10: Technical Drawing

    2.0 Specification 2.2 Technical Drawing 2.2.1 GL720TGCT 700 Series Model GL720TGCT Gas Char Grill 400mm Description Countertop Weight 55kg Overall Height 416mm Overall Depth 720mm Overall Width 400mm Natural Universal LPG Gas Connection 1/2'' BSP 1/2'' BSP Minimum Normal Test Gas Pressure 1.3 kPa...
  • Page 11 700/900 2.2.3 GL740TGCT 700 Series Model GL740TGCT Gas Char Grill 800mm Description Countertop Weight 70kg Overall Height 416mm Overall Depth 720mm Overall Width 800mm Natural Universal LPG Gas Connection 1/2'' BSP 1/2'' BSP Minimum Normal Test Gas Pressure 1.3 kPa 2.75 kPa Maximum Normal Test Gas Pressure 3.5 kPa...
  • Page 12 2.2.5 GL920TGCT 900 Series Model GL920TGCT Gas Char Grill 400mm Description Countertop Weight 70kg Overall Height 416mm Overall Depth 920mm Overall Width 400mm Natural Universal LPG Gas Connection 1/2'' BSP 1/2'' BSP Minimum Normal Test Gas Pressure 1.3 kPa 2.75 kPa Maximum Normal Test Gas Pressure 3.5 kPa 3.5 kPa...
  • Page 13 700/900 2.0 Specification 2.2.7 GL920TGCT 900 Series Model GL940TGCT Gas Char Grill 800mm Description Countertop Weight 110kg Overall Height 416mm Overall Depth 920mm Overall Width 800mm Natural Universal LPG Gas Connection 1/2'' BSP 1/2'' BSP Minimum Normal Test Gas Pressure 1.3 kPa 2.75 kPa Maximum Normal Test Gas Pressure...
  • Page 14: Installation

    3.0 Installation 3.1 Positioning WARNING Improper installation, adjustments, alterations, service or maintenance can cause property damage, injury or death. 3.1.1 General Information • The unit must be installed under an extraction canopy • Have a smooth, level floor which can bear the weight of the unit at full load •...
  • Page 15 700/900 3.0 Installation 3.2 Line-up Connection WARNING Must be installed only by an authorised service person If the unit is already installed and connected to power, the power to the equipment must be turned off and isolated. FAILURE TO DO SO MAY RESULT IN ELECTRIC SHOCK. •...
  • Page 16 3.0 Installation • Place the units to be connected next to each other, adjust the legs ensuring the top of the two units sit flush • Using the provided bolts and nuts connect the units at the front and rear •...
  • Page 17: Gas Connection

    700/900 3.0 Installation 3.3 Gas Connection WARNING This unit must be installed by an authorised person/installer in accordance with this instruction manual, AS/NZS 5601 – Gas installations (installation and pipe sizing), local gas fitting regulations, local electrical regulations, local water regulations, local health regulations, Building Code of Australia and any other government authority.
  • Page 18: Gas Pressure Check

    3.0 Installation 3.3.3 Gas Pressure Check Ensure Burner Gas pressure matches the rating label (see page 8 / 2.1.4 Fig 1.). If the gas operating pressure is incorrect, adjust pressure regulator installed on the incoming gas supply to the unit. The operating pressure is measured at the pressure outlet test point (fig 4).
  • Page 19: Gas Conversion

    700/900 3.0 Installation 3.4 Gas Conversion IMPORTANT Gas Conversion must only be carried out by an authorised person. Incorrect installation may void warranty If the unit is to be connected to a different type of gas than that for which it has been prepared, the nozzles must be replaced. Please contact Stoddart for the approved Gas conversion Kit and settings.
  • Page 20: Operation

    4.0 Operation 4.1 Lava Stones 4.1.1 Lava Stone Placement Remove the char grill rack Evenly spread the lava stones over the grid rack Fig.9. DO NOT overlap or bunch the lava stones Fig.10. DO NOT use any materials other than lava stone (e.g. wood, charcoal, etc.) Re-install the char grill rack Fig.9.
  • Page 21 700/900 4.0 Operation 4.2 Operation WARNING Hot surfaces! DO NOT TOUCH Contact with skin may cause burns WARNING DO NOT spray aerosols in the vicinity of the appliance when operating. 4.2.1 Controller Configuration Control Panel - Hi-Lo Symbol Description Pilot Flame Large Flame (Maximum Power) Small Flame (Minimum Power) Piezo ignition...
  • Page 22: Cleaning And Maintenance

    5.0 Cleaning and Maintenance 5.1 Cleaning 5.1.1 Cleaning Schedule • Daily cleaning is required for the appliance, to help maintain and prolong the appliance efficiency • The appliance should be cleaned at the end of each service period • DO NOT USE: Wire brushes, steel wool/sponges, scrapers or other abrasive materials •...
  • Page 23 700/900 5.0 Cleaning and Maintenance 5.1.6 Cleaning Procedure (Daily) Using a scraper remove crumbs and small food items from the steel plate Remove the drip tray and empty. Clean with warm soapy water and thoroughly dry Remove the char grill ash tray and empty. if required, clean with warm soapy water and thoroughly dry Note: The drip tray should be checked regularly inspected and emptied as required.
  • Page 24: Periodic Maintenance

    5.0 Cleaning and Maintenance 5.2 Maintenance WARNING Maintenance tasks are only to be completed by authorised service people 5.2.1 Periodic Maintenance All controls and mechanical parts of the appliance should be checked and adjusted periodically by a qualified service person. Contact the Stoddart service department to arrange a service Maintenance / Inspections Possible Causes...
  • Page 25 700/900 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 24...
  • Page 26 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 25...
  • Page 27 700/900 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 26...
  • Page 28 Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au Service Request www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz Email: sales@stoddart.co.nz Email: spares@stoddart.co.nz...

Table of Contents