AXIS P32 Dome Camera Series
Specifications
1
Pin
Function
Ground
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Supervised input - Enables possibility to detect tampering on a digital input.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, trough an event or from the product's webpage.
A digital light sensor - For receiving a value of the ambient light intensity from an external light sensor. This is used to control the
product's day and night functionality.
Note
The I/O connector is connected to the housing (fan/heater) on delivery. In case of a fan or heater error, an input signal will be
triggered in the camera. Set up an action rule in the camera to configure which action the signal shall trigger.
4-pin terminal block
6-pin terminal block
Function
DC ground
DC output
2
Balanced Microphone Hot (+) In
Pin
Notes
1
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Balanced Microphone Cold (-) In
60
Specifications
0 V DC
12 V DC
Max load = 25 mA