Dip Switch Pack S2; S2-1: Baud Rate; S2-2: Handshake Flags; S2-3: Parity On/Off - Filtec FT-50c Service And Technical Reference Manual

Fill level inspector
Table of Contents

Advertisement

FT-50 Fill Level Inspector Service Manual

Dip Switch Pack S2

Slide Switches

10-6

S2-1: Baud Rate

Defines the baud rate (bits per second) for the user serial port
(RS-422/423) as either 1200 or 9600. The default is 1200 baud.

S2-2: Handshake Flags

Enables the use of the Serial Hardware Handshake lines. The
default is off.

S2-3: Parity On/Off

Enables the parity bit in the Serial Data transmission. The default is
off.

S2-4: Parity Odd/Even

Allows selection of odd or even parity when S2-3 is open. The
default is odd.

S2-5: Character Size

Allows selection of 7 or 8 bit characters. The default is 8 bit.

S2-6: Multi-Serial

Enables the FT-50 for a multiple unit serial network and switches
the serial port from active open to tri-state, RS-485. The default is
RS-485.

S2-7: Led Section Selector

Defines current LED section. The default is section 1.

S2-8: Led Bank Selector

Defines current logical LED bank. The default is bank 1.

SW3

Selects either RS-232 or RS-422/485 network communications. The
default is RS-232.
Industrial Dynamics Company, Ltd. Document 40255-0600

Advertisement

Table of Contents
loading

Table of Contents