Troubleshooting Problems With Rejectors; Proline Rejector Troubleshooting - Filtec FT-50c Service And Technical Reference Manual

Fill level inspector
Table of Contents

Advertisement

FT-50 Fill Level Inspector Service Manual

Troubleshooting Problems with Rejectors

8-22

Proline Rejector Troubleshooting

The rejector is operating erratically.
1. The air supply may be erratic. Verify the air pressure is in the
proper operational range for the rejector.
2. Check to see if the cylinder is binding by shutting of the air
pressure to the rejector and moving the rejector in and out by
hand. If it is binding, rebuild the rejector with a rebuild kit.
3. The rejector Pulse Width function may need adjustment.
Contact IDC Customer Support for assistance.
The rejector remains extended.
1. Turn the FT-50's power off. If the rejector remains extended,
repair or replace the Rejector Assembly.
2. Close dip switch S2-8 on the FT-50 processor card and then
turn cycle the power.
• If LED 2 remains on, replace the processor card.
• If the warning beacon is on and LED 2 is off, replace the
power supply.
Industrial Dynamics Company, Ltd. Document 40255-0600