Target Head Height

Allows you to record the Inspection Head height setting for the
current container configuration.
To record the Target Head Height:
1. Press Key 1 until you reach TARGET HEAD HEIGHT.
2. Read the value displayed in the Head Height Counter. The
counter is located in the upper left corner on the front of the
FT-50 (see illustration 4-2).
3. Use the Arrow Key to enter the value in the TARGET HEAD
HEIGHT function.

Gamma Threshold

Establishes the threshold value that the Gamma Counts must:
• exceed for underfill rejection
• not exceed for overfill rejection
Any gamma count value that falls outside of the Gamma
Threshold triggers a rejection.

Looktime Gate

The time in milliseconds during which gamma counts are recorded
for each container. The Looktime Gate Value is determined by the
containers width at the inspection point and the conveyor speed.
In simplified terms it is the amount of time the container requires
to pass through the gamma inspection beam. See also Time Width
of Can.

Fill Level Optimization

The Fill Level Optimization routine is used to increase fill level
inspection accuracy for applications that require higher accuracy
than is achieved through normal fill level inspection parameters. It
narrows the margin between acceptable and rejectable containers.
See Chapter 6: Fill Level Optimization for more information.