Quick Reference Troubleshooting Guide - Filtec FT-50c Service And Technical Reference Manual

Fill level inspector
Table of Contents

Advertisement

Industrial Dynamics Company, Ltd. Document 40255-0600

Quick Reference Troubleshooting Guide

Possible Cause
Containers are not rejected.
Rejector is not being
energized by inspection unit.
Insufficient or no compressed
air.
Air lines contaminated or
blocked.
Air pressure incorrect.
Rejector assembly has
malfunctioned.
Containers improperly
positioned on the conveyor.
All containers are rejected.
The fill level calibration is
incorrect and all containers
are registering as rejects.
Chapter 8: Diagnostic and Repair Procedures
Corrective Action
Is the inspector detecting any rejects? Pass a
reject test can through the Inspection
System. With the reject switch set to ON, the
rejector should fire and the Reject LED on the
processor card should flash.
Open valve to air supply and adjust regulator
air pressure to 65 psi.
Check all air lines to be sure they are free
from contamination and that air passes
through them freely.
Adjust pressure to setting established during
calibration procedure.
Inspect the rejector arm as described in the
Routine Preventative Maintenance
procedures
Review the Installation section for proper
installation.
Repeat the Fill Level Calibration Procedure to
establish the correct fill level inspection
parameters.
continued on next page
8-25