Diagnostic Error Messages

Industrial Dynamics Company, Ltd. Document 40255-0600
The amber Warning Beacon on top of the Inspection Head signals
an alarm or error condition by blinking rapidly.
1. Press the Question Mark Key to view the error number in the
LCD.
2. Press the Arrow Key to scroll through the error description and
to clear the error condition. When you clear the error the
message resets to zero.
Error Number 2
An attempt was made to activate the rejector while the Rejector
Status Function is turned off.
To correct this error, turn the Rejector Status Function on.
Error Number 5
The maximum limit of 32 containers between the trigger beam and
the rejector has been exceeded.
Measure the container's width at the point where the inspection
trigger contacts the container and verify that this value is the value
in the Can Width At Trig Function.
Error Number 6
A consecutive reject timing error that occurs when an encoder
pulse is missed. One pulse per container is required, and starting
and stopping the conveyor suddenly while a container is in the
inspection trigger zone, or improper encoder calibration caused a
missed pulse.
To correct this error, calibrate the encoder, or replace the encoder.
Error Number 8
The EEPROM cannot be erased. This error indicates that either
switch S11 is not set to the Write Enabled position or that EEPROM
chip U29 is faulty.
To correct this error, set switch S11 to the Write Enabled position
(position A), or replace EEPROM chip U29.